• AU series
  • AU series

AU series

Low profile and High power Rack-mount type high voltage power supply

  • Max Voltage: 1kV to 120kV
  • Max Current: 0.25mA to 2200mA
  • Max Power: 30W to 2200W
  • CE marking(For some models)

Best and Long Seller of Rack-mount type High Voltage power supply!

AU series is a high performance, high-reliability and high-quality DC high voltage power supply as a result of our high-voltage power technology built up over the years. High efficiency and ultra miniaturization is realized with our switching and voltage isolation technology.

With wide lineup of over 300 models and various options the best suitable model for your application can be selected from the output range of 1 kV to 120 kV/30 W to 2.2 kW. AU series has various remote control and monitor functions as standard, and by adding digital control interface it will contribute to the extensibility for ATE (Automatic Test Equipment) system as well as to various high-voltage experiments and to evaluations of inverters and power devices. AU series is only a third to a half size of conventional power supplies and dedicated to compactness of device and saving space of facilities. Double and triple protections are added for even safer operation. With new master-slave option higher power output operation is now possible.

Features and Benefits

  • Wide output range from 1 kV to 120 kV and 30 W to 2.2 kW
  • Low profile and lightweight
  • Local and remote operation
  • Front panel adjustable overload trip level
  • Remote and front panel monitoring of DC output voltage and current
  • Automatic protection against overload, short circuit and arc
  • Greater than 85% efficiency
  • GP-IB interface is available and programable with optional GP-IB units
  • CE Certified; up to 300 W models excluding 1.5 kV

Wide range of lineup

The best output range and function from abundance of lineup of 1kV to 120 kV/30 W to 2.2 kW, over 300 models can be selected. Therefore no need to choose a product with over output or specifications avoiding wasted investment.
AU series has -LC option for automatic switch of constant voltage/constant current modes as well as other various options such as different input voltage or slow ramp up are available.

Full of remote function

High-voltage output voltage and output current (output cut off value for standard type, and current limit value for AU with -LC option) can be controlled. Also equipped with output ON/OFF, monitor output for voltage/current and status output of high voltage is equipped and door switch is standard as a safety function.
Also interface of GPIB, RS-232C, RS-485 and USB can be added as an option for computer control.
A system integrartion with other measuring instruments or control devices can be constructed for faster testing and development. It's easy to build a system up with the combination of our DC (low voltage) power supplies or AC power supplies.

Ultra low profile/space saving

Panel height is only 1.73" (models less than 1 kV to 60 kV/30 W to 300 W models) and 19-inch standard rack mount type. Miniaturization and high reliability that are conflicting themes for high-voltage power supplies are cleared by our high voltage insulation technology.
AU series has been receiving good reputation for applications requires space saving such as inspection system of production line, or requires combination several power supplies.

HV Power Supplies AU Series Feature

Applications

  • Evalution for inverters or power devices (IGBT, MOS-FET)
  • ATE (Automatic Test Equipment)
  • Electron Beams
  • Ion Beams
  • X-ray tube
  • Aging of electronic components
  • Capacitor Charging
  • Insulator Testing
  • All kinds of High-Voltage Testing

Models

CE mark
CE marking models.
They correspond to Low Voltage Directive and EMC Directive.
As for CE marking,the modeks which have not yet acquired CE marking at present are going to acquire them in the near future.
If you need the latest information about the status of the acquisition,
please contact the nearest sales office.

Positive polarity output

Model Output Safety standards
Voltage [kV] Current [mA] Power [W]
AU-1P30 1 30 30 CE mark
AU-1P60 60 60 CE mark
AU-1P100 100 100 CE mark
AU-1P150 150 150 CE mark
AU-1P300 300 300 CE mark
AU-1P600 600 600
AU-1P1200 1200 1200
AU-1P2200 2200 2200
AU-1.5P200 1.5 200 300
AU-1.5P400 400 600
AU-1.5P800 800 1200
AU-1.5P1460 1460 2200
AU-2P15 2 15 30 CE mark
AU-2P30 30 60 CE mark
AU-2P50 50 100 CE mark
AU-2P75 75 150 CE mark
AU-2P150 150 300 CE mark
AU-2P300 300 600
AU-2P600 600 1200
AU-2P1100 1100 2200
AU-3P10 3 10 30 CE mark
AU-3P20 20 60 CE mark
AU-3P33 33 100 CE mark
AU-3P50 50 150 CE mark
AU-3P100 100 300 CE mark
AU-3P200 200 600
AU-3P400 400 1200
AU-3P733 733 2200
AU-5P6 5 6 30 CE mark
AU-5P12 12 60 CE mark
AU-5P20 20 100 CE mark
AU-5P30 30 150 CE mark
AU-5P60 60 300 CE mark
AU-5P120 120 600
AU-5P240 240 1200
AU-5P440 440 2200
AU-6P5 6 5 30 CE mark
AU-6P10 10 60 CE mark
AU-6P16 16 100 CE mark
AU-6P25 25 150 CE mark
AU-6P50 50 300 CE mark
AU-6P100 100 600
AU-6P200 200 1200
AU-6P366 366 2200
AU-10P3 10 3 30 CE mark
AU-10P6 6 60 CE mark
AU-10P10 10 100 CE mark
AU-10P15 15 150 CE mark
AU-10P30 30 300 CE mark
AU-10P60 60 600
AU-10P120 120 1200
AU-10P220 220 2200
AU-15P2 15 2 30 CE mark
AU-15P4 4 60 CE mark
AU-15P6.6 6.6 100 CE mark
AU-15P10 10 150 CE mark
AU-15P20 20 300 CE mark
AU-15P40 40 600
AU-15P80 80 1200
AU-15P146 146 2200
AU-20P1.5 20 1.5 30 CE mark
AU-20P3 3 60 CE mark
AU-20P5 5 100 CE mark
AU-20P7.5 7.5 150 CE mark
AU-20P15 15 300 CE mark
AU-20P30 30 600
AU-20P60 60 1200
AU-20P110 110 2200
AU-30P1 30 1 30 CE mark
AU-30P2 2 60 CE mark
AU-30P3.3 3.3 100 CE mark
AU-30P5 5 150 CE mark
AU-30P10 10 300 CE mark
AU-30P20 20 600
AU-30P40 40 1200
AU-30P73.3 73.3 2200
AU-40P0.75 40 0.75 30 CE mark
AU-40P1.5 1.5 60 CE mark
AU-40P2.5 2.5 100 CE mark
AU-40P3.75 3.75 150 CE mark
AU-40P7.5 7.5 300 CE mark
AU-40P15 15 600
AU-40P30 30 1200
AU-40P55 55 2200
AU-50P0.6 50 0.6 30 CE mark
AU-50P1.2 1.2 60 CE mark
AU-50P2 2 100 CE mark
AU-50P3 3 150 CE mark
AU-50P6 6 300 CE mark
AU-50P12 12 600
AU-50P24 24 1200
AU-50P44 44 2200
AU-60P0.5 60 0.5 30 CE mark
AU-60P1 1 60 CE mark
AU-60P1.6 1.6 100 CE mark
AU-60P2.5 2.5 150 CE mark
AU-60P5 5 300 CE mark
AU-60P10 10 600
AU-60P20 20 1200
AU-60P36.6 36.6 2200
AU-80P0.37 80 0.37 30 CE mark
AU-80P0.75 0.75 60 CE mark
AU-80P1.25 1.25 100 CE mark
AU-80P1.87 1.87 150 CE mark
AU-80P3.75 3.75 300 CE mark
AU-80P7.5 7.5 600
AU-80P15 15 1200
AU-80P27.5 27.5 2200
AU-100P0.3 100 0.3 30 CE mark
AU-100P0.6 0.6 60 CE mark
AU-100P1 1 100 CE mark
AU-100P1.5 1.5 150 CE mark
AU-100P3 3 300 CE mark
AU-100P6 6 600
AU-100P12 12 1200
AU-100P22 22 2200
AU-120P0.25 120 0.25 30 CE mark
AU-120P0.5 0.5 60 CE mark
AU-120P0.83 0.83 100 CE mark
AU-120P1.25 1.25 150 CE mark
AU-120P2.5 2.5 300 CE mark
AU-120P5 5 600
AU-120P10 10 1200
AU-120P18.3 18.3 2200

Negative polarity output

Model Output Safety standards
Voltage [kV] Current [mA] Power [W]
AU-1N30 1 30 30 CE mark
AU-1N60 60 60 CE mark
AU-1N100 100 100 CE mark
AU-1N150 150 150 CE mark
AU-1N300 300 300 CE mark
AU-1N600 600 600
AU-1N1200 1200 1200
AU-1N2200 2200 2200
AU-1.5N200 1.5 200 300
AU-1.5N400 400 600
AU-1.5N800 800 1200
AU-1.5N1460 1460 2200
AU-2N15 2 15 30 CE mark
AU-2N30 30 60 CE mark
AU-2N50 50 100 CE mark
AU-2N75 75 150 CE mark
AU-2N150 150 300 CE mark
AU-2N300 300 600
AU-2N600 600 1200
AU-2N1100 1100 2200
AU-3N10 3 10 30 CE mark
AU-3N20 20 60 CE mark
AU-3N33 33 100 CE mark
AU-3N50 50 150 CE mark
AU-3N100 100 300 CE mark
AU-3N200 200 600
AU-3N400 400 1200
AU-3N733 733 2200
AU-5N6 5 6 30 CE mark
AU-5N12 12 60 CE mark
AU-5N20 20 100 CE mark
AU-5N30 30 150 CE mark
AU-5N60 60 300 CE mark
AU-5N120 120 600
AU-5N240 240 1200
AU-5N440 440 2200
AU-6N5 6 5 30 CE mark
AU-6N10 10 60 CE mark
AU-6N16 16 100 CE mark
AU-6N25 25 150 CE mark
AU-6N50 50 300 CE mark
AU-6N100 100 600
AU-6N200 200 1200
AU-6N366 366 2200
AU-10N3 10 3 30 CE mark
AU-10N6 6 60 CE mark
AU-10N10 10 100 CE mark
AU-10N15 15 150 CE mark
AU-10N30 30 300 CE mark
AU-10N60 60 600
AU-10N120 120 1200
AU-10N220 220 2200
AU-15N2 15 2 30 CE mark
AU-15N4 4 60 CE mark
AU-15N6.6 6.6 100 CE mark
AU-15N10 10 150 CE mark
AU-15N20 20 300 CE mark
AU-15N40 40 600
AU-15N80 80 1200
AU-15N146 146 2200
AU-20N1.5 20 1.5 30 CE mark
AU-20N3 3 60 CE mark
AU-20N5 5 100 CE mark
AU-20N7.5 7.5 150 CE mark
AU-20N15 15 300 CE mark
AU-20N30 30 600
AU-20N60 60 1200
AU-20N110 110 2200
AU-30N1 30 1 30 CE mark
AU-30N2 2 60 CE mark
AU-30N3.3 3.3 100 CE mark
AU-30N5 5 150 CE mark
AU-30N10 10 300 CE mark
AU-30N20 20 600
AU-30N40 40 1200
AU-30N73.3 73.3 2200
AU-40N0.75 40 0.75 30 CE mark
AU-40N1.5 1.5 60 CE mark
AU-40N2.5 2.5 100 CE mark
AU-40N3.75 3.75 150 CE mark
AU-40N7.5 7.5 300 CE mark
AU-40N15 15 600
AU-40N30 30 1200
AU-40N55 55 2200
AU-50N0.6 50 0.6 30 CE mark
AU-50N1.2 1.2 60 CE mark
AU-50N2 2 100 CE mark
AU-50N3 3 150 CE mark
AU-50N6 6 300 CE mark
AU-50N12 12 600
AU-50N24 24 1200
AU-50N44 44 2200
AU-60N0.5 60 0.5 30 CE mark
AU-60N1 1 60 CE mark
AU-60N1.6 1.6 100 CE mark
AU-60N2.5 2.5 150 CE mark
AU-60N5 5 300 CE mark
AU-60N10 10 600
AU-60N20 20 1200
AU-60N36.6 36.6 2200
AU-80N0.37 80 0.37 30 CE mark
AU-80N0.75 0.75 60 CE mark
AU-80N1.25 1.25 100 CE mark
AU-80N1.87 1.87 150 CE mark
AU-80N3.75 3.75 300 CE mark
AU-80N7.5 7.5 600
AU-80N15 15 1200
AU-80N27.5 27.5 2200
AU-100N0.3 100 0.3 30 CE mark
AU-100N0.6 0.6 60 CE mark
AU-100N1 1 100 CE mark
AU-100N1.5 1.5 150 CE mark
AU-100N3 3 300 CE mark
AU-100N6 6 600
AU-100N12 12 1200
AU-100N22 22 2200
AU-120N0.25 120 0.25 30 CE mark
AU-120N0.5 0.5 60 CE mark
AU-120N0.83 0.83 100 CE mark
AU-120N1.25 1.25 150 CE mark
AU-120N2.5 2.5 300 CE mark
AU-120N5 5 600
AU-120N10 10 1200
AU-120N18.3 18.3 2200

Reversible polarity output

Model Output Safety standards
Voltage [kV] Current [mA] Power [W]
AU-1R30 1 30 30 CE mark
AU-1R60 60 60 CE mark
AU-1R100 100 100 CE mark
AU-1R150 150 150 CE mark
AU-1R300 300 300 CE mark
AU-1R600 600 600
AU-1R1200 1200 1200
AU-1R2200 2200 2200
AU-1.5R200 1.5 200 300
AU-1.5R400 400 600
AU-1.5R800 800 1200
AU-1.5R1460 1460 2200
AU-2R15 2 15 30 CE mark
AU-2R30 30 60 CE mark
AU-2R50 50 100 CE mark
AU-2R75 75 150 CE mark
AU-2R150 150 300 CE mark
AU-2R300 300 600
AU-2R600 600 1200
AU-2R1100 1100 2200
AU-3R10 3 10 30 CE mark
AU-3R20 20 60 CE mark
AU-3R33 33 100 CE mark
AU-3R50 50 150 CE mark
AU-3R100 100 300 CE mark
AU-3R200 200 600
AU-3R400 400 1200
AU-3R733 733 2200
AU-5R6 5 6 30 CE mark
AU-5R12 12 60 CE mark
AU-5R20 20 100 CE mark
AU-5R30 30 150 CE mark
AU-5R60 60 300 CE mark
AU-5R120 120 600
AU-5R240 240 1200
AU-5R440 440 2200
AU-6R5 6 5 30 CE mark
AU-6R10 10 60 CE mark
AU-6R16 16 100 CE mark
AU-6R25 25 150 CE mark
AU-6R50 50 300 CE mark
AU-6R100 100 600
AU-6R200 200 1200
AU-6R366 366 2200
AU-10R3 10 3 30 CE mark
AU-10R6 6 60 CE mark
AU-10R10 10 100 CE mark
AU-10R15 15 150 CE mark
AU-10R30 30 300 CE mark
AU-10R60 60 600
AU-10R120 120 1200
AU-10R220 220 2200
AU-15R2 15 2 30 CE mark
AU-15R4 4 60 CE mark
AU-15R6.6 6.6 100 CE mark
AU-15R10 10 150 CE mark
AU-15R20 20 300 CE mark
AU-15R40 40 600
AU-15R80 80 1200
AU-15R146 146 2200
AU-20R1.5 20 1.5 30 CE mark
AU-20R3 3 60 CE mark
AU-20R5 5 100 CE mark
AU-20R7.5 7.5 150 CE mark
AU-20R15 15 300 CE mark
AU-20R30 30 600
AU-20R60 60 1200
AU-20R110 110 2200
AU-30R1 30 1 30 CE mark
AU-30R2 2 60 CE mark
AU-30R3.3 3.3 100 CE mark
AU-30R5 5 150 CE mark
AU-30R10 10 300 CE mark
AU-30R20 20 600
AU-30R40 40 1200
AU-30R73.3 73.3 2200
AU-40R0.75 40 0.75 30 CE mark
AU-40R1.5 1.5 60 CE mark
AU-40R2.5 2.5 100 CE mark
AU-40R3.75 3.75 150 CE mark
AU-40R7.5 7.5 300 CE mark
AU-40R15 15 600
AU-40R30 30 1200
AU-40R55 55 2200
AU-50R0.6 50 0.6 30 CE mark
AU-50R1.2 1.2 60 CE mark
AU-50R2 2 100 CE mark
AU-50R3 3 150 CE mark
AU-50R6 6 300 CE mark
AU-50R12 12 600
AU-50R24 24 1200
AU-50R44 44 2200
AU-60R0.5 60 0.5 30 CE mark
AU-60R1 1 60 CE mark
AU-60R1.6 1.6 100 CE mark
AU-60R2.5 2.5 150 CE mark
AU-60R5 5 300 CE mark
AU-60R10 10 600
AU-60R20 20 1200
AU-60R36.6 36.6 2200
AU-80R0.37 80 0.37 30 CE mark
AU-80R0.75 0.75 60 CE mark
AU-80R1.25 1.25 100 CE mark
AU-80R1.87 1.87 150 CE mark
AU-80R3.75 3.75 300 CE mark
AU-80R7.5 7.5 600
AU-80R15 15 1200
AU-80R27.5 27.5 2200
AU-100R0.3 100 0.3 30 CE mark
AU-100R0.6 0.6 60 CE mark
AU-100R1 1 100 CE mark
AU-100R1.5 1.5 150 CE mark
AU-100R3 3 300 CE mark
AU-100R6 6 600
AU-100R12 12 1200
AU-100R22 22 2200
AU-120R0.25 120 0.25 30 CE mark
AU-120R0.5 0.5 60 CE mark
AU-120R0.83 0.83 100 CE mark
AU-120R1.25 1.25 150 CE mark
AU-120R2.5 2.5 300 CE mark
AU-120R5 5 600
AU-120R10 10 1200
AU-120R18.3 18.3 2200

[e.g.] AU-1R30: 0V to ±1 kV/0 A to 30 mA

Positive, negative or reversible high voltage respect to chassis ground.
Units from 1 kV to 6 kV, the polarity may be reversed by swapping the internal cables.
Units from 10 kV to 120 kV, by swapping the internal high voltage module.
Following lineups are also avaliable beside above.
AK series: 1 kV to 120 kV/3 kW to 6.4 kW
AKP series: 1 kV to 120 kV/12 kW, 13 kW
REH series: 750 V to 1.2 kV/1 kW to 15 kW

Appearance

Normal operation (1) -> (2) -> (9) -> (10), coversely to stop operation

HV Power Supplies AU Series Functions 1 HV Power Supplies AU Series Functions 2
  1. POWER ON/OFF switch
    This has priority ober all operations for safety.
  2. OUTPUT ON/OFF button
    Used for urgent OFF or resume the output when mode as well as output ON/OFF when local mode. Also used for manual recovery of protection function. (Output is possible only when OUTPUT button is ON even when remote)
  3. OUTPUT ON Display LED
    Lights up in a status when output is possible or when output. (Goes off when cut off by protection circuit)
  4. External control display
    Lights up during external control.
  5. Door switch display LED
    Lights up when door switch operates. (output cut off during the light is on)
  6. Over temperature protection display LED
    Lights up when internal part reaches excess temperature by abnormal heating.
  7. Operation mode display LED
    Lights up during operation of constant voltage.
  8. Operation mode display LED
    Lights up when over current is cut off. Lights up during operation of constant current (unit with -LC option).
  9. Output Voltage adjustable potentiometer (10-turn, lockable)
  10. Output Current adjustable potentiometer (10-turn, lockable)
  11. Output connector (Matsuda's property)
  12. GND Terminal (M6)
  13. S2 switch
  14. AC input connector
    up to 300 W models: Inlet
    600 W to 2.2 kW models:Terminal (M4)

Functions

REMOTE CONTROL CONNECTOR (TB1)

D-Sub 25pin female (mating connector enclosed). Use for GPIB connection too.

REMOTE/LOCAL change

REMOTE/LOCAL change
Model Output relay Open collector
REMOTE SHORT Vce ≤ 0.4 V
LOCAL OPEN VCE ≥ 2 V

Sink Current ≥ 10mA

Remote HV ON/OFF

Remote HV ON/OFF
Output Output relay Open collector
ON SHORT Vce ≤ 0.4 V
OFF OPEN Vce ≥ 2 V

Sink Current ≥ 10mA

OUTPUT CONTROL Remote analog programing

  • It is possible to conduct control with the combination of Vcon and output current setting potentiometer (10) of front panel.
  • Open circuit (fixed at MAX value) is possible by entering Vref.
OUTPUT CONTROL Remote analog programing
Output Voltage LRv Vcon
0 to MAX R2:
0 Ω to 5 kΩ
0 V to 10 V
Input impedance ≥ 1MΩ
OUTPUT CONTROL Remote analog programing
Output Current * LRc Vcon
0 to MAX R2:
0 Ω to 5 kΩ
0 V to 10 V
Input impedance ≥ 1MΩ

* Model with -LC

OUTPUT MONITOR AND STATUS

OUTPUT MONITOR AND STATUS

Internal relay of status output turns ON in a status when output is possible or when output (entrained to OUTPUT ON display LED). Contact open-circuit voltage 30 V, permissible current 100 mA max.

DOOR SWITCH

DOOR SWITCH

It is possible to output in external relay short or a status of VCE less than 0.4 V. Output will be cut off when open or 2 V or more. To resume the output again, turn OUTPUT button ON after resetting by turning OUTPUT button OFF in a status of short or less than 0.4 V.

Sink Current ≥ 10 mA

* Door switch becomes effective when S2 terminal is open.

REMOTE RESET

REMOTE RESET (HABb)
Output relay Output relay Timing
SHORT Vce ≤ 0.4 V Timing
OPEN Vce ≥ 2 V

Sink Current ≥ 10mA

-LF option: FLOATING GROUND TERMINAL (M3)

FLOATING GROUND TERMINAL (-LF option)

Case GND "CASE" and power supply GND "0 V" can be isolated up to 50 V. Minimal current in load can be measured by measuring the current between these 2 points to avoid the effect of ground noise.

  • * Not for floating applications
  • * All equipments that connect to Remote Control Connector (TB1) must be on floating ground in case this feature is intended to use.

Options

-LStc: Constant Curreent status signal

Constant Current mode or when OCP (Over Current Protection)
activated, the open collector will turn on. (Vce > 2 V)

-LStv: Constant Voltage status signal

When operation mode is Constant Voltage mode,the open collector will turn on.(Vce > 2V)

-LC: Constant voltage and constant current *2

Current regulation 0.05%
(-LC option eliminates Overload Trip function)

-LF: Floating ground (withstanding voltage of 50Vdc) *1

Used when measuring minimal current in load.
All equipments that connect to Remote Control Connector (TB1) must be on floating ground in case this feature is intended to use.
(Cannot be used for the purpose of floating high-voltage power supply.)

-LMs: Master slave control (600 W, 1.2 kW and 2.2 kW models only) *1*2*3

Maximum of 4 slave units can be controlled with one master unit.

-LW: Slow start *1

Takes about 10 seconds to reach a set voltage from when OUTPUT switch, remote switch and remote switch are turned on.

-L(220V)

200Vac to 240Vac single phase input. (30 W to 300 W models only)

-L(115V)

100Vac to 120Vac single phase input. (600 W models only)

-L(U)

Input voltage switch over 100Vac to 120Vac/200Vac to 240Vac single phase input.
Internal switch over. (30 W to 300 W models only)

-L(200V3P)

Ithree-phase input (2200 W models only)

-L(3m)

The length of HV output shielded cable is changed to 3 m.

-L(5m)

The length of HV output shielded cable is changed to 5 m. (only for 40 kV models)

-L(7m)

The length of HV output shielded cable is changed to 7 m. (only for 15 kV models)

-LPs: Setting value display

The set voltage value and the set current value are displayed on the meter,while you pressing the SET button on the front panel.
(This button is attached only when -LPs option is chosen.)

  1. In case selecting -LMs option with -LF option or -LW option, all AU power supplies which connected as Master-Slave, need to equip -LF option or -LW option.
  2. In case power supply operate as cut off the output when overcurrent with Master-Slave connection, do not select -LC option for Master unit (the other options can be selected), and select -LC option for only Slave unit (the other options can be also selected together). Combinations other than above, cut off the output when overcurrent will not work.
    And also, Slave unit is equipped with -LC option, therefore, if Slave unit is used indivdually, out will be either CV or CC.
  3. In case you operate power supplies with CV/CC mode under Master-Slave connection, select -LC option for Master unit and all Slave units (the other options can be also selected together). Combinations other than above, CV/CC will not work.
    And also, Master unit and each Slave unit equipped with -LC option, therefore, if each unit is used individually, out will be either CV or CC.

Cable

Input Cable

CABLE TYPE 1

125 V/10 A

for 30 W to 300 W models
  • CABLE TYPE 1
  • CABLE TYPE 1

CABLE TYPE 3

250 V/10 A

for 30 W to 300 W models (with -L(220V) option)
  • CABLE TYPE 3
  • CABLE TYPE 3

CABLE TYPE 5

250 V/25 A

for 600 W, 1200 W, 2200 W models
  • CABLE TYPE 5
  • CABLE TYPE 5

CABLE TYPE 6 *

250 V/25 A

for 2200 W models (with -L(220V3P) option)
  • CABLE TYPE 6
  • CABLE TYPE 6

*Please purchase it separately

Output Cable

CN-*-MHVP

for 30 W to 1200 W/2200 W (≧ 2 kV) models

  • CN-*-MHVP

Depending on outoput voltage, length will be varied.
Please contact nearby sales office for details.

CN-15PR-MHVP

for 2200 W (1 kV, 1.5 kV) models

  • CN-15PR-MHVP

Download

The account registration is necessary for downloading

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Please click here if you are not registered yet to our site.

Membership Registration (Free)

Please click here if you are already registered to our site.

Log in

High Voltage power supplies (Rack Mount/Benchtop)

Search for related to High Voltage power supplies (Rack Mount/Benchtop)