ULTRA-LOW NOISE HIGH STABILITY HIGH VOLTAGE POWER SUPPLY
High Voltage Power Supply Featuring Ultra-Low Noise High Stability is Ideally Suited for Reference Voltage Source with High Accuracy.
- Output Voltage: ±3100V
- Output Current: 0 to 5mA
- Rated Output Power: 15.5W
- Bestseller
Top Class Quality with Low Ripple 1mVp-p
ASX series, an advanced high voltage power supply, features the world highest level of noise reduction and high stability. With the ultra-low noise of ripple 1 mVp-p as well as high stability of 50 ppm/H at ±3.1 kV output, the series is one of the most popular high voltage power supplies among various research institutes in Japan and all over the world.
In addition, the ASX series offers the digital setting system having a large-sized five-digit meter and three rotary encoder switches, so you can perform the quick and accurate setting at full scale output voltage of 170 ppm. ASX series is especially suited for driving photomultiplier tubes (PMT) used in low-light-level measurement which could be adversely affected by very small noise and aging.
FEATURES AND BENEFITS
- Ultra-low Noise
- Ultra-low noise 1mVp-p at rated output voltage ±3.1 kV
- Outstanding operability
- Quick and accurate setting of output voltage with the digital setting system having a five-digit display of setting voltage and three rotary encoder switches used separately for the digits
- Designing highly reliable system
- High reliability of all solid state design equipped with many protection functions as standard
APPLICATIONS
- Reference power supply
- Photomultiplier Tube (PMT)
- Microchannel Plate (MCP)
- Photo Detector
- Geiger counter, Radiation detection
- Nuclear equipment
- Precise measurement
Models
Specifications
Options
- -LA:
-
Remote terminal is supplied (providing the following features).
-
Interlock
High voltage output cut off by external switch -
External output ON/OFF
High voltage output ON/OFF by external relay -
Output voltage monitor
0 to ±10 V/maximum output voltage (output impedance 1 kΩ) same polarity as high voltage output
-
Interlock
- -LC
-
Current limit
Limits output current by dropping output voltage.
- -LG
-
GPIB control
For output ON/OFF,output voltage setting (resolution 0.1 V) and switching polarity.
- -LMh
-
A load side of the output cable will be MHV plug.
- -LRs
-
RS-232C control
For output ON/OFF,output voltage setting (resolution 0.1 V) and switching polarity.
- -LSh
-
A load side of -LSh the output cable will be SHV plug.
- -LW
-
Slow start
Takes about 10 seconds to reach a set voltage after turning on the output.
(Takes about 5 seconds if setting half of the output voltage.)
- -L(3m), -L(5m), -L(7m)
-
High voltage output shielded cable length change
Please choose high voltage output cable length from 3 meters, 5 meters, 7 meters.
(Please contact nearby sales office if specific length other than above.)
-LRs option and -LG option cannot be selected together. Need to be selected either one.
How to Order
When ordering, add Option No. to Model No. in alphabetical order followed by the cable length.
Example: ASX-3R5-LACGMhW(3m), ASX-3R5-5-LACRsShW(7m)
Accessories
Sold separately | CABLE TYPE1 | 125 V / 10 A rating | 2.5 meters Fixed length |
---|
Standard | CN-BNC-HVP | ![]() |
2.5 meters (Fixed length) |
---|---|---|---|
Standard (-LMh option) |
CN-BNC-HVPP (With MHV connector) |
![]() |
2.5 meters (Fixed length) |
Standard (-LSh option) |
CN-BNC-HVPSP (With SHV connector on a load side) |
![]() |
2.5 meters (Fixed length) |
Dimensions
Download
-
ASX series Datasheet
Date: 2023-07-28 Rev. 07
PDF (1,547 KB)
-
Safety and Usage of High voltage Power supply
Date: 2023-07-27 rev. 03
PDF (602 KB)
-
High Performance High Voltage Power Supplies
Date: 2023-10-06 rev. 12
PDF (3,886 KB)
-
ASX series Instruction Manual
Last updated: April 3, 2020 rev.2.8
PDF (351 KB)
The account registration is necessary for downloading
-
ASX series Datasheet
Date: 2023-07-28 Rev. 07
PDF (1,547 KB)
-
Safety and Usage of High voltage Power supply
Date: 2023-07-27 rev. 03
PDF (602 KB)
-
High Performance High Voltage Power Supplies
Date: 2023-10-06 rev. 12
PDF (3,886 KB)
-
ASX series Instruction Manual
Last updated: April 3, 2020 rev.2.8
PDF (351 KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.
Please click here if you are not registered yet to our site.
Please click here if you are already registered to our site.
Information on related articles in Technical Knowledge
- Safety and Usage of High Voltage Power Supply
- How to Select a High Voltage Power Supply for Analyzers
- Mass Spectrometry Power Supply Total Solutions!
- High voltage power supplies for Scanning Electron Microscope and Mass Spectrometry
- What to do if you get electrocuted? What to do in case of electric shock(electrical injury) and how to handle high voltage