ULTRA HIGH SPEED HIGH VOLTAGE AMPLIFIER
- Voltage range:
±0.6kV to ±10kV - Power:
200W to 100W - Slew rate:
360V/µs - Full scale:
DC to 100kHz - Small bandwidth:
DC to 100kHz
Rack Mountable Type High Voltage Amplifier
AMS/AMT series are a rack mountable, fast response, high voltage operational amplifier that have been developed base on our many years of experience and expertise in high voltage. With a fast response up to 100 kHz, the AMS/AMT series can output high voltagein sine, triangle, sawtooth, and square waves proportional to the input waveform.
We have eight models with output voltage ranging from ±0.6 kV to ±10 kV, which are all solid-state.
FEATURES AND BENEFITS
- Output ±0.6 kV to ±10 kV
- High speed response, max. 100 kHz
- Various types of output wave forms according to the input wave
- DC bias function
- DC output voltage monitor (3.5-digit digital meter)
APPLICATIONS
- Beam deflection
- Corona discharge
- Dielectric withstand test
- Electrostatic chuck
- Electrophotography process
- Electrorheological (ER) fluids
- Lighting test for discharge tube, Gas Discharge Tube (GDT)
- Various electrostatic testing
Models
Model | Output | Slew rate | Frequency response (-3dB) *1 | CE marking *2 | |||
---|---|---|---|---|---|---|---|
Voltage [kVdc] | Current [max] | Power [max] | Full scale | 10% of full scale | |||
AMS-5B6 | -5 to +5 kV | ±6 mA | 30 W | 30 V/µs | DC to 2 kHz | DC to 4 kHz | |
AMS-10B2 | -10 to +10 kV | ±2 mA | 20 W | 30 V/µs | DC to 1 kHz | DC to 2 kHz |
Model | Output | Slew rate | Frequency response (-3dB) *1 | CE marking *2 | |||
---|---|---|---|---|---|---|---|
Voltage [kVdc] | Current [max] | Power [max] | Full scale | 10% of full scale | |||
AMT-0.6B100 | -0.6 to +0.6 kV | ±100 mA | 60 W | 250 V/µs | DC to 100 kHz | DC to 100 kHz | - |
AMT-1B60 | -1 to +1 kV | ±60 mA | 60 W | 250 V/µs | DC to 60 kHz | DC to 100 kHz | - |
AMT-1.5B40 | -1.5 to +1.5 kV | ±40 mA | 60 W | 250 V/µs | DC to 40 kHz | DC to 80 kHz | - |
AMT-3B20 | -3 to +3 kV | ±20 mA | 60 W | 360 V/µs | DC to 30 kHz | DC to 60 kHz | - |
AMT-5B20 | -5 to +5 kV | ±20 mA | 100 W | 360 V/µs | DC to 20 kHz | DC to 40 kHz | |
AMT-10B10 | -10 to +10 kV | ±10 mA | 100 W | 360 V/µs | DC to 10 kHz | DC to 20 kHz |
*1 Typical value at sine wave.
*2 Conform to CE marking with -CE option selected.
Discontinued models
The following model is no longer available as we have stopped the production and sales. AMPS-0.6B2000 is available as the successor model.
Model | Output | Slew rate | Frequency response (-3dB) * | |||
---|---|---|---|---|---|---|
Voltage [kVdc] | Current [max] | Power [max] | Full scale | 10% of full scale | ||
AMS-0.6B50 | -0.6 to +0.6 kV | ±50 mA | 30 W | 30 V/µs | DC to 15 kHz | DC to 30 kHz |
AMS-1B30 | -1 to +1 kV | ±30 mA | 30 W | 30 V/µs | DC to 10 kHz | DC to 20 kHz |
AMS-1.5B20 | -1.5 to +1.5 kV | ±20 mA | 30 W | 30 V/µs | DC to 6 kHz | DC to 12 kHz |
AMS-3B10 | -3 to +3 kV | ±10 mA | 30 W | 30 V/µs | DC to 3 kHz | DC to 6 kHz |
Model | Output | Slew Rate | Frequency Response (-3dB) * | |||
---|---|---|---|---|---|---|
Voltage [kVdc] | Current [mA] | Power [W] | Full scale | 10% of full scale | ||
AMT-20B10 | -20 to +20 kV | ±10 mA | 200 W | 360 V/µs | DC to 5 kHz | DC to 10 kHz |
Specifications
Options
- -LC
-
Current Limit
Limits the output current at time of overload
- -LN
-
Output state auto-recovery
(former: no power failure protection)
- -L1
-
Output current monitor
-10 V to +10 V from BNC connector on front panel
(output impedance 1 kΩ up to 2 kHz bandwidth)
- -L(230V)
-
Input Voltage 230 Vac ±10% single phase
(unavailable with -CE option selected)
- -L(5m)
-
High Voltage output cable 5 meters
Note that phenomena such as through rate or response speed reduced, or output waveform distorted may happen.
- -CE
-
Conform to CE marking with Input voltage 100 Vac to 240 Vac
(For available models, see “Models” CE marking)
Conforms to CE marking safety standards with the input voltage 100 Vac to 240 Vac ±10%, 50 Hz/60 Hz, single phase.
* The product is designed to be installed in the customer’s system and so as to meet the requirements of CE marking regarding chassis mounting, noise control, proper protections, and isolated devices. It is not designed to perform alone.
How to order
When ordering, add Option No. to Model No.
(in alphabetical order, followed by number order, input voltage order, and output cable length order. Please add -CE to the end.)
Example: AMS5B6-LC, AMS-5B6-LCN1(230V)(5m)
Example of ordering -CE option: AMS-5B6-CE, AMS-5B6-LCN1(5m)-CE
Accessories
Standard | CABLE TYPE1 | Rated voltage: 125 V Maximum current: 10 A (For Japan or North America) |
2.5 meters | ||
---|---|---|---|---|---|
Standard with -L(230V) option |
CABLE TYPE3 | Rated voltage: 250 V Maximum current: 10 A (For Europe) |
2.5 meters | ||
Sold separately with -L(230V) option |
CABLE TYPE4 | Rated voltage: 250 V Maximum current: 10 A (For Europe) |
2.5 meters |
Select an appropriate AC input cable according to your operating environment and region. Please note that other than AC input cables that correspond to the following are to be prepared by customers.
Standard | CN-40-AHVP | ![]() |
1.5 meters |
---|---|---|---|
Standard with -L(5m) option |
CN-40-AHVP(5) | 5 meters |
* Standard cable length is 1.5 meters. For 5 meter length, suffix(5) to the model number.
Example CN-120AR-MHVP(5)
For more details, refer to CN series.
Dimensions
Tech Notes
Capacitive Load
When a capacitive load is more than 100 pF (including a stray capacitance of output wire), the resonance in the output may occur. In that case, install 100 Ω (at 0.1 μF) to 1000 Ω (at 1000 pF) of high voltage resistance in the output in series. Please note that the frequency band will be limited as the formula written in the right figure when an amplifier is used with a capacitive load.
In addition, when an amplifier is used for the use such as a corona discharge, the current which is higher than rating will flow and it will affect the amplifier badly. In this case, as well as the time to use an amplifier with a capacitive load, please install the output resistance and limit the current.
* Please avoid continuous inputting of high frequency signal which reduces output frequency of an amplifier. An amplifier will be broken because of increase of internal loss.

Download
-
AMS/AMT series Datasheet
Date: 2023-11-14 rev.12
PDF (3,866 KB)
-
High Speed, High Voltage Amplifier Selection Guide
Date: 2023-07-26 rev.18
PDF (4,266 KB)
-
Bipolar Power Supplies/Amplifiers Selection Guide
Date: 2023-10-17 rev.03
PDF (6,310 KB)
-
Safety and Usage of High voltage Power supply
Date: 2023-07-27 rev. 03
PDF (602 KB)
-
AMS series Instruction Manual
Date: 2023-4-27 rev.8.1
PDF (835 KB)
-
AMT series Instruction Manual
Date: 2023-4-27 rev.4.1
PDF (723 KB)
The account registration is necessary for downloading
-
AMS/AMT series Datasheet
Date: 2023-11-14 rev.12
PDF (3,866 KB)
-
High Speed, High Voltage Amplifier Selection Guide
Date: 2023-07-26 rev.18
PDF (4,266 KB)
-
Bipolar Power Supplies/Amplifiers Selection Guide
Date: 2023-10-17 rev.03
PDF (6,310 KB)
-
Safety and Usage of High voltage Power supply
Date: 2023-07-27 rev. 03
PDF (602 KB)
-
AMS series Instruction Manual
Date: 2023-4-27 rev.8.1
PDF (835 KB)
-
AMT series Instruction Manual
Date: 2023-4-27 rev.4.1
PDF (723 KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.