Ultra Fast Response High-Voltage Amplifier
- ±0.6kV to ±40kV
±10mA to ±2000mA
100W to 1200W
Slew Rate:
≥ 700V/µs
Full Scale:
DC to 40kHz
Small Bandwidth:
DC to 60kHz
When you need more options and high-quality engineering, the AMP series delivers elite wideband performance and stability with nine distinct models, a wide output voltage range from ±0.6 kV to ±40 kV, and a max slew rate of ≥ 700V/µs.
Featuring three types of peak current output (four, three, or two times the rated value), the AMP Series also uses a current sink function that allows for a four-quadrant bipolar power supply.
Ideal for solar panel (photovoltaics cell) evaluations, corona discharge testing, as well as many other applications.
Applications
- Solar panel (Photovoltaics cell) evaluations
- Corona discharge
- Electrophotography
- High Speed Printers
- Material Evaluation Testing
- Piezo drivers
- Electrostatic chuck
- Dielectric Breakdown Testing
Features
- Range: ±0.6 kV to ±40 kV
- Four-quadrant operation of V and I with the bipolar amplifier
- Drive capacitive loads via a four-quadrant output
- Response: 1 kHz to 40 kHz
- Current sink function enables evaluation of I-V characteristics of solar cells (photovoltaic cells)
- Peak current output of three times the rated value (Models in ±10 kV to ±30 kV)
- Conforms with European health, safety, and environmental protection standards for low-voltage electrical equipment***
- CE marking (low voltage directive conformed)
-
No More Response Delay (Slew Rate: 700 V/µs)
By achieving a slew rate of 700 V/µs at the actual load, the AMP series minimizes response delay in action operation with the load; this is suitable for high-speed printers and material evaluation testing.
Waveform Example model AMP-20B20 Operation Condition Vcon-in ±10 V Vout = ± 20 kV
RL = 1 MΩ F = 1.25 kHzSlew Rate SR = 32000 V/40 µs > 700 V/µs -
Eco-Friendly & Designed for High Voltage Power Devices
Featuring high speed, high voltage, low loss, and low energy loss, our new power semiconductors, such as SiC and GaN, actively contribute to low-carbon operations.
Models
Models with ±40 kV or more are available. Consult with our representatives.
Model | Output | Slew rate | Frequency response (-3 dB) *1 | Safety standards | |||
---|---|---|---|---|---|---|---|
Voltage | Current (DC + AC) | Maximum Power |
Full scale *2 | Small bandwidth (10% of full scale) |
|||
AMP-0.6B2000 | -0.6 to +0.6 kV | ±2000 mA max and ±4000 mA peak 1 ms max |
1200 W | ≥ 300 V/µs | DC to 40 kHz | DC to 60 kHz | |
AMP-1B1200 | -1 to +1 kV | ±1200 mA max and ±2400 mA peak 1 ms max |
1200 W | ≥ 300 V/µs | DC to 30 kHz | DC to 50 kHz | - |
AMP-2B200 | -2 to +2 kV | ±200 mA max and ±400 mA peak 1 ms max |
400 W | ≥ 700 V/µs | DC to 20 kHz | DC to 50 kHz | |
AMP-5B80 | -5 to +5 kV | ±80 mA max and ±160 mA peak 1 ms max |
400 W | ≥ 700 V/µs | DC to 10 kHz | DC to 30 kHz | |
AMP-10B10 | -10 to +10 kV | ±10 mA max and ±40 mA peak 1 ms max |
100 W | ≥ 700 V/µs | DC to 7 kHz | DC to 25 kHz | |
AMP-10B40 | -10 to +10 kV | ±40 mA max and ±120 mA peak 1 ms max |
400 W | ≥ 700 V/µs | DC to 7 kHz | DC to 25 kHz | |
AMP-20B20 | -20 to +20 kV | ±20 mA max and ±60 mA peak 1 ms max |
400 W | ≥ 700 V/µs | DC to 4 kHz | DC to 20 kHz | |
AMP-30B10 | -30 to +30 kV | ±10 mA max and ±30 mA peak 1 ms max |
300 W | ≥ 360 V/µs | DC to 1 kHz | DC to 5 kHz | - |
AMP-40B20 | -40 to +40 kV | ±20 mA max and ±40 mA peak 1 ms max |
800 W | ≥ 360 V/µs | DC to 1 kHz | DC to 5 kHz | - |
: Conform to the CE (with low voltage directive) marking
- Typical value at sine wave operation with resistive load
- Near to the upper limit frequency, output voltage may be clipped due to the power limitation.
Specifications
AMP Series Options
A flexible array of options allows you to pick and choose the features that best fit your application. You can reduce costs and maximize efficiency without sacrificing quality.
-LC
Current limit level *
The output is not turned off but it is limited in the event of lowering output voltage a -LC t overcurrent level.
-LCc
Adjustable current limit level *
The output is not turned off but it is limited in the event of lowering output voltage at an overcurrent level.
Using the potentiometer on the front panel, the limit current level can be adjusted in the range of 10% to 105% of the rating.
Both -LOc (adjustable current trip level) and -LCc (adjustable current limit level) are switchable.
-LCx
Adjustable current trip level + Variable current limit level *
May switch between -LOc (variation of current cutoff ) and -LCc (variable current limit). NOTE: Models with -LCx option do not comply with CE Marking for low voltage.
-LN
Output state auto-recovery
(former: no power failure protection)
-LOc
Adjustable current trip level *
Using the potentiometer on the front panel, the limit value to turn off the output current can be adjusted in the range of 10% to 105% of the rating.
L(5m)
High voltage output cable 5 meters (only 1 kV to 10 kV output models and 20 kV model output can select this option.)
When using a cable 5 meters long, phenomena such as lower through rate or response speed or output waveform distortion may occur easily. Be careful to use it.
* Only one option may be chosen per device at this time.
How to Order
When ordering, add Option No. in the following order:
- Alphabet,
- Number,
- Input voltage, and
- Output cable length to Model No.
Example: AMP-10B10-LCN(5m), AMP-2B200-LNOc(5m)
Accessories
Input Cable
Standard AMP-10B10 |
CABLE TYPE1 | 125 V / 10 A | 2.5 meters Fixed length |
||
---|---|---|---|---|---|
Standard 300 W and 400 W Models |
CABLE TYPE3 | 250 V / 10 A | 2.5 meters Fixed length |
||
Standard 800 W, 1200 W Models |
CABLE TYPE5 | 250 V / 25 A | 2.5 meters |
View CABLE series catalog for details
Output Cable
Standard 0.6 kV model |
Using terminal block output line 1.5 meters | ||
---|---|---|---|
Standard 1 kV to 10 kV models |
CN-40-AHVP | High voltage output cable 1.5 meters |
|
Standard 1 kV to 10 kV models [with -L(5m) option] |
CN-40-AHVP(5) | High voltage output cable 5 meters |
|
Standard AMP-20B20 |
CN-40-AHVP TU | High voltage output cable 1.5 meters |
|
Standard AMP-20B20 [with -L(5m) option] |
CN-40-AHVP TU(5) | High voltage output cable 5 meters |
|
Standard AMP-30B10, AMP-40B20 |
CN-50-AHVP | High voltage output cable 3 meters |
Dimensions
Download
If you are unable to download a file
Please try the following solution.
- Please press Ctrl+F5 to clear the cache of your web browser and try again.
- Please restart your web browser and log in again to try again.
- Please change your web browser to another browser and try again.
- Restart the computer and try again.
- Please try again on a different computer.
-
AMP series Datasheet
Date: 2023/07/26 rev.13
PDF (2,277 KB)
-
High Speed, High Voltage Amplifier Selection Guide
Date: 2023-07-26 rev.18
PDF (4,266 KB)
-
Bipolar Power Supplies/Amplifiers Selection Guide
Date: 2023-10-17 rev.03
PDF (6,310 KB)
-
Safety and Usage of High voltage Power supply
Date: 2023-07-27 rev. 03
PDF (602 KB)
-
AMP series Manual
Date: 2022/9/27 rev 2.2
PDF (1,366 KB)
Login Required
-
AMP series Datasheet
Date: 2023/07/26 rev.13
PDF (2,277 KB)
-
High Speed, High Voltage Amplifier Selection Guide
Date: 2023-07-26 rev.18
PDF (4,266 KB)
-
Bipolar Power Supplies/Amplifiers Selection Guide
Date: 2023-10-17 rev.03
PDF (6,310 KB)
-
Safety and Usage of High voltage Power supply
Date: 2023-07-27 rev. 03
PDF (602 KB)
-
AMP series Manual
Date: 2022/9/27 rev 2.2
PDF (1,366 KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.