X-ray Inspection system

COMPACT & HIGH-RESOLUTION
Benchtop Entry Model

  • Max X-ray voltage : 60kV
  • Focal spot size : 5μm
  • Maximum monitor image magnification
    125 times
  • Inspection area
    2.5 × 2.8mm to 4.7 × 5.3mm
CE

Features

Suitable for Small Parts

"precision μB 3200" is a benchtop entry-level X-ray inspection system. The compact X-ray inspection system fits directly on the desk to use it anywhere at small factories or offices.
And, you can adjust the geometric magnification of the sample by raising or lowering the detector position.

Suitable for small parts

Size of Stage, Shooting Range by the Movement

The "precision μB3200" is ideal for taking images of small circuit boards and small components. For example, the maximum monitor image magnification of 125 times, the inspection area is 2.5 mm × 2.8 mm, and the applicable shooting range is 150 mm × 200 mm.

stage size
Door open.png

Sample on the stage

Door open

ample on the stage

Reasons of Compact

Point
  • Using exquisitely created high voltage power supply
  • New design for longer life
  • Short FOD
compact

For the Safety

The X-ray leakage measurement we offer is conducted from all directions of each unit to confirm that it is less than 1μSv/hr before delivery.
It is the extremely low level that has no impact on the usage in daily lives.

Four features that enhance safety
  • Interlock
  • Auto-off
  • Product status display LED
  • Emergency stop button
For details, download the datasheet below.

Notification

Notifications to the public authorities (government offices, municipalities, etc.) in each country may be required for the installation of X-ray equipment. Please contact our sales representative if you need any necessary information.

X-Ray Shielding Technology

To ensure safe and reliable installation, we have carefully designed radiation shielding.
In general, lead used for shielding is a soft and easily deformed material, but by adopting a multi-layered structure combined with steel plates, it can be used for a long time without deformation of lead.

shield

Easy Replacement

X-ray tube unit replacement steps

To replace the X-ray tube unit, remove the panels on the top and at the back side, and pull out the X-ray tube unit from the bottom part.

tube unit
X-ray detector replacement

Slide off the detector attached on the top inside of the unit to replace it with new one.

camera
camera
For details, download the datasheet below.

Model

Model X-ray tube Stage
Anode voltage Anode current Focal spot size Perimetry field Maximum monitor magnification
precision µB3200 30 kV to 60 kV 150 µA MAX 5 µm 2.5 mm × 2.8 mm to 4.7 mm × 5.3 mm 125 times

Functions

Brightness adjustment

brightness
brightness

The brightness of the X-ray images can be arranged by adjusting the gain value and tone curve. Also, the automatic adjustment is available.

Contrast adjustment

contrast
contrast

The contrast of the X-ray image can be adjusted by changing the gamma value and brightness range. The automatic adjustment is also available.

Specifications

For details, download the datasheet below.

Options

-LF3
Digital Flat Panel High resolution detector
detector Gradations 16,384 (14 bits)
Resolution 3 million pixels
Inspection area 3.0 mm × 5.2 mm to 5.8 mm × 10.3 mm
Maximum monitor magnification 103 times
Monitor size 27 inches
CE to be marked

Accessories

Power Cable

Power cables for the product, computer, and monitor are not supplied. Please select the appropriate cable for your operating environment and region (see the table below), or prepare your own.

AC Input Cable
CABLE TYPE1 CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 125 V / 10 A
CABLE TYPE8 CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 125 V / 125 A
CABLE TYPE3
European Standard supported
CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 250 V / 10 A
CABLE TYPE4
European Standard supported
CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 250 V / 10 A
Up and Down Stage

STG002: size 120 mm × 120 mm
STG056: size 120 mm × 140 mm

The stage helps you to raise its height, therefore, the sample can be closer to the X-ray camera for shooting, so you can take larger field images.

Applications

Sample Images

Printed circuit board

Circuit board – wire bonding

Tube voltage : 60 kV
Tube current : 150 μA
Monitor image magnification : 20 times

Printed circuit board – wire bonding

Circuit board

Tube voltage : 60 kV
Tube current : 150 μA
Monitor image magnification : 125 times

Printed circuit board – BGA

Circuit board – BGA

Tube voltage : 60 kV
Tube current : 150 μA
Monitor image magnification : 125 times

Fields and Applications of X-ray Radiography Non-Destructive Testing

Pharmaceuticals and Cosmetics
Tablets, Capsules, Catheters, Medical pouches, Foreign object in the face mask, Cosmetics
Automobiles and Electric Vehicles
Automotive components, Wire harness, Batteries, Molded plastic parts, Motor, Insert molded parts, Aluminum die casting, Sensor, Mating parts connection
Electronics
Ball grid array (BGA), Integrated circuit (IC) chip, Connectors, Capacitors, LED, Relays, Printed circuit board (PCB), AC adapter, Light bulbs filament, Electrical cable disconnects, Discharge traces of dielectric breakdown
Advanced Materials
Carbon-Fiber-Reinforced Polymers (CFRP), Insulation material, Carbon, Dissimilar material joint, Contamination in beryllium
Precision Conponents
Probe, Bearing, Mating of plastic parts, Spring position
Creatures and Plants
Laboratory rats, Seeds, Flowers, Shell, Bone, Insects, Rice
Others
Microscopic foreign matter contamination, Voids in welding, Plastic bottle, Sealing of cans

FAQ for performance of X-Ray Inspection System

X-Ray Inspection System FAQ

Download

If you are unable to download a file

Please try the following solution.

  1. Please press Ctrl+F5 to clear the cache of your web browser and try again.
  2. Please restart your web browser and log in again to try again.
  3. Please change your web browser to another browser and try again.
  4. Restart the computer and try again.
  5. Please try again on a different computer.

The account registration is necessary for downloading

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Please click here if you are not registered yet to our site.

Membership Registration (Free)

Please click here if you are already registered to our site.

Log in

X-ray Inspection Systems

Search for related to X-ray Inspection Systems