• AE/AF series
  • AE/AF series

AE/AF series

Low noise power supply
Precision rack mount

  • Max Voltage: 1kV to 150kV
  • Max Current: 0.2mA to 120mA
  • Max Power: 15W to 300W
  • Local and remote operation

Wide line-up of high voltage power supply from 1 kV to 150 kV and 30 W to 300 W

AF series is one of the best seller model of Matsusada as high performance standard high voltage power supply. AE series has even greater ripple noise and stability, and has long been selected from various national laboratories.

We succeed to keep the ripple and spike noise low with our proprietary switching circuit, and it provides highly stable HV output with well-selected components and highly-stabilized circuit. They are well suited for R&D applications which require high accuracy, and among then for Electron Microscope and Mass spectrometer application AE/AF series demonstrate outstanding performance.

Needless to say its reliability has been proved high with its long history, and in addition it has double and triple protections for safer operations. Various remote control and monitor functions are equipped as standard for building systems.

Features and Benefits

  • Low ripple 10 ppm, High stability 50 ppm/Hr. (AE series)
  • Wide lineup of high voltage power supply from 1 kV to 150 kV and 30 W to 300 W
  • Local and remote operation
  • Front panel adjustable overload trip level
  • Remote and front panel monitoring of DC output voltage and current
  • Automatic protection against overload, short circuit and arc.
  • GPIB interface option
  • Digital interface option

Applications

  • Electron Microscope
  • Stand power Supply
  • Electronic component evaluation test
  • Electron Beams
  • X-ray tube
  • Electron gun
  • Ion Beams
  • Insulator Testing
  • Lithography
  • SEM
  • All kinds of High-Voltage Testing

Models

AE series (ultra low ripple)

Positive polarity output

Model Max Output
Voltage [kVdc] Current [mA] Power [W] Ripple [rms]
AE-1P15 1 15 15 10 ppm
AE-1P30 30 30
AE-3P10 3 10 30 10 ppm
AE-3P20 20 60
AE-5P6 5 6 30 10 ppm
AE-5P12 12 60
AE-10P3 10 3 30 10 ppm
AE-10P6 6 60
AE-20P1.5 20 1.5 30 10 ppm
AE-20P3 3 60
AE-30P1 30 1 30 10 ppm
AE-30P2 2 60
AE-40P0.75 40 0.75 30 10 ppm
AE-40P1.5 1.5 60
AE-50P0.5 50 0.5 25 10 ppm
AE-50P1 1 50
AE-60P0.5 60 0.5 30 10 ppm
AE-60P1 1 60
AE-80P0.3 80 0.3 24 10 ppm
AE-80P0.75 0.75 60
AE-100P0.3 100 0.3 30 10 ppm
AE-120P0.25 120 0.25 30 10 ppm
AE-120P1 1 120
AE-150P0.2 150 0.2 30 10 ppm

Negative polarity output

Model Max Output
Voltage [kVdc] Current [mA] Power [W] Ripple [rms]
AE-1N15 1 15 15 10 ppm
AE-1N30 30 30
AE-3N10 3 10 30 10 ppm
AE-3N20 20 60
AE-5N6 5 6 30 10 ppm
AE-5N12 12 60
AE-10N3 10 3 30 10 ppm
AE-10N6 6 60
AE-20N1.5 20 1.5 30 10 ppm
AE-20N3 3 60
AE-30N1 30 1 30 10 ppm
AE-30N2 2 60
AE-40N0.75 40 0.75 30 10 ppm
AE-40N1.5 1.5 60
AE-50N0.5 50 0.5 25 10 ppm
AE-50N1 1 50
AE-60N0.5 60 0.5 30 10 ppm
AE-60N1 1 60
AE-80N0.3 80 0.3 24 10 ppm
AE-80N0.75 0.75 60
AE-100N0.3 100 0.3 30 10 ppm
AE-120N0.25 120 0.25 30 10 ppm
AE-120N1 1 120
AE-150N0.2 150 0.2 30 10 ppm
Example:
AE-150N0.2: to -150 kV/0.2 mA

Reversible polarity output

Unit less than 60 kV, the polarity may be reversed by swapping the internal cable. Unit over 80 kV, by swapping internal high voltage module.

Model Max Output
Voltage [kVdc] Current [mA] Power [W] Ripple [rms]
AE-1R15 1 15 15 10 ppm
AE-1R30 30 30
AE-3R10 3 10 30 10 ppm
AE-3R20 20 60
AE-5R6 5 6 30 10 ppm
AE-5R12 12 60
AE-10R3 10 3 30 10 ppm
AE-10R6 6 60
AE-20R1.5 20 1.5 30 10 ppm
AE-20R3 3 60
AE-30R1 30 1 30 10 ppm
AE-30R2 2 60
AE-40R0.75 40 0.75 30 10 ppm
AE-40R1.5 1.5 60
AE-50R0.5 50 0.5 25 10 ppm
AE-50R1 1 50
AE-60R0.5 60 0.5 30 10 ppm
AE-60R1 1 60

AF series (low ripple)

Positive polarity output

Model Max Output
Voltage [kVdc] Current [mA] Power [W] Ripple [rms]
AF-1P30 1 30 30 100 ppm
AF-1P60 60 60
AF-1P120 120 120
AF-3P10 3 10 30 100 ppm
AF-3P20 20 60
AF-3P40 40 120
AF-3P60 60 180
AF-3P80 80 240
AF-5P6 5 6 30 100 ppm
AF-5P12 12 60
AF-5P25 25 125
AF-5P35 35 175
AF-5P50 50 250
AF-10P3 10 3 30 100 ppm
AF-10P6 6 60
AF-10P12 12 120
AF-10P18 18 180
AF-10P25 25 250
AF-10P30 30 300
AF-20P1.5 20 1.5 30 100 ppm
AF-20P3 3 60
AF-20P6 6 120
AF-20P9 9 180
AF-20P12 12 240
AF-20P15 15 300
AF-30P1 30 1 30 100 ppm
AF-30P2 2 60
AF-30P4 4 120
AF-30P6 6 180
AF-30P8 8 240
AF-30P10 10 300
AF-40P0.75 40 0.75 30 100 ppm
AF-40P1.5 1.5 60
AF-40P3 3 120
AF-40P4.5 4.5 180
AF-40P6 6 240
AF-40P7.5 7.5 300
AF-50P0.6 50 0.6 30 100 ppm
AF-50P1.2 1.2 60
AF-50P2.5 2.5 125
AF-50P3.5 3.5 175
AF-50P5 5 250
AF-60P0.5 60 0.5 30 100 ppm
AF-60P1 1 60
AF-60P2 2 120
AF-60P3 3 180
AF-60P4 4 240
AF-80P0.75 80 0.75 60 100 ppm
AF-80P1.5 1.5 120
AF-100P0.1 100 0.1 10 100 ppm
AF-100P0.3 0.3 30
AF-100P0.6 0.6 60
AF-100P1 1 100
AF-100P1.2 1.2 120
AF-120P0.5 120 0.5 60 100 ppm
AF-120P1 1 120
AF-150P0.5 150 0.5 75 100 ppm
AF-150P0.8 0.8 120

Negative polarity output

Model Max Output
Voltage [kVdc] Current [mA] Power [W] Ripple [rms]
AF-1N30 1 30 30 100 ppm
AF-1N60 60 60
AF-1N120 120 120
AF-3N10 3 10 30 100 ppm
AF-3N20 20 60
AF-3N40 40 120
AF-3N60 60 180
AF-3N80 80 240
AF-5N6 5 6 30 100 ppm
AF-5N12 12 60
AF-5N25 25 125
AF-5N35 35 175
AF-5N50 50 250
AF-10N3 10 3 30 100 ppm
AF-10N6 6 60
AF-10N12 12 120
AF-10N18 18 180
AF-10N25 25 250
AF-10N30 30 300
AF-20N1.5 20 1.5 30 100 ppm
AF-20N3 3 60
AF-20N6 6 120
AF-20N9 9 180
AF-20N12 12 240
AF-20N15 15 300
AF-30N1 30 1 30 100 ppm
AF-30N2 2 60
AF-30N4 4 120
AF-30N6 6 180
AF-30N8 8 240
AF-30N10 10 300
AF-40N0.75 40 0.75 30 100 ppm
AF-40N1.5 1.5 60
AF-40N3 3 120
AF-40N4.5 4.5 180
AF-40N6 6 240
AF-40N7.5 7.5 300
AF-50N0.6 50 0.6 30 100 ppm
AF-50N1.2 1.2 60
AF-50N2.5 2.5 125
AF-50N3.5 3.5 175
AF-50N5 5 250
AF-60N0.5 60 0.5 30 100 ppm
AF-60N1 1 60
AF-60N2 2 120
AF-60N3 3 180
AF-60N4 4 240
AF-80N0.75 80 0.75 60 100 ppm
AF-80N1.5 1.5 120
AF-100N0.1 100 0.1 10 100 ppm
AF-100N0.3 0.3 30
AF-100N0.6 0.6 60
AF-100N1 1 100
AF-100N1.2 1.2 120
AF-120N0.5 120 0.5 60 100 ppm
AF-120N1 1 120
AF-150N0.5 150 0.5 75 100 ppm
AF-150N0.8 0.8 120

Reversible polarity output

Unit less than 60 kV, the polarity may be reversed by swapping the internal cable. Unit over 80 kV, by swapping internal high voltage module.

Model Max Output
Voltage [kVdc] Current [mA] Power [W] Ripple [rms]
AF-1R30 1 30 30 100 ppm
AF-1R60 60 60
AF-1R120 120 120
AF-3R10 3 10 30 100 ppm
AF-3R20 20 60
AF-3R40 40 120
AF-3R60 60 180
AF-3R80 80 240
AF-5R6 5 6 30 100 ppm
AF-5R12 12 60
AF-5R25 25 125
AF-5R35 35 175
AF-5R50 50 250
AF-10R3 10 3 30 100 ppm
AF-10R6 6 60
AF-10R12 12 120
AF-10R18 18 180
AF-10R25 25 250
AF-10R30 30 300
AF-20R1.5 20 1.5 30 100 ppm
AF-20R3 3 60
AF-20R6 6 120
AF-20R9 9 180
AF-20R12 12 240
AF-20R15 15 300
AF-30R1 30 1 30 100 ppm
AF-30R2 2 60
AF-30R4 4 120
AF-30R6 6 180
AF-30R8 8 240
AF-30R10 10 300
AF-40R0.75 40 0.75 30 100 ppm
AF-40R1.5 1.5 60
AF-40R3 3 120
AF-50R0.6 50 0.6 30 100 ppm
AF-50R1.2 1.2 60
AF-50R2.5 2.5 125
AF-60R0.5 60 0.5 30 100 ppm
AF-60R1 1 60
AF-60R2 2 120
AF-80R0.75 80 0.75 60 100 ppm
AF-100R0.1 100 0.1 10 100 ppm
AF-100R0.3 0.3 30
Example:
AF-1R30: 0 V to ±1 kV/0 A to 30 mA

Functions

Normal Operation: Output (1) to (5), conversely to stop operation.

HV Power Supplies AE/AF series Front panel HV Power Supplies AE/AF series Rear panel
  1. POWER ON/OFF switch: This has priority over all operations.
  2. HV ON/OFF switch
    Output is enable when this is ON.
    Remote switch can be turned ON/OFF only when HV switch is ON. This switch is also used for resetting interlock and cut off mode.
  3. COARSE potentiometer (10-turn, lockable)
  4. FINE potentiometer (10-turn, lockable)
  5. Overload trip level setting dial: 1-turn LED is lit up when protection circuit is operating.
  6. GND Terminal (M6)
  7. AC Inlet
  8. Fuse
  9. Output connector (Matsusada's property)
  10. Output voltage monitor
  11. Output current monitor
  12. Connector for USB, RS-232C, RS-485, and GPIB interface, and changing-over switch (option)

REMOTE CNTROL CONNECTOR M4

REMOTE SWITCH ON/OFF *

REMOTE SWITCH ON/OFF
Output External relay Open collector
ON Short VCE ≤ 0.4 V
OFF Open VCE ≥ 2 V

Sink Current ≥ 10 mA

OUTPUT CONTROL

OUTPUT CONTROL
Output voltage LR Vcon
0 to MAX R2
0 Ω to 5 kΩ
0 V to 10 V
Input imp ≥ 10 kΩ

Output is possible in external relay short or a status of VCE less than 0.4 V.
Output will be cut off when open or 2 V or remote. To Output again, turn OUTPUT switch ON after resetting by turning OUTPUT switch OFF in a status of short or 0.4 V or less.

* -LG option: When switch (12) is on IEEE-488 side, remote switch and output control is not enable from remote terminal, but from only IEEE-488 operation.

DOOR SWITCH

DOOR SWITCH

Sink Current ≥ 10 mA

Output is possible in external relay short or a status of VCE less than 0.4 V.

Output will be cut off when open or 2 V or mote. To output again, tum OUTPUT switch ON after resetting by turning OUTPUT switch OFF in a status of short or 0.4 V or less.

* -LG option: When switch (12) is on IEEE-488 side, remote switch and output control is not enable from remote terminal, but from only IEEE-488 operation.

OUTPUT MONITOR BNC receptacle *

OUTPUT MONITOR BNC receptacle  *
  • Vout: 0 V to ±10 V(0 V to +10 V)
    • [standard] Monitor polarity equals output polarity
    • [-LG option] Positive polarity regardless of HV polarity
  • Iout: 0 V to +10 V

Output imp is 1 kΩ.

* -LG option: Generates output no matter switch (12) is on or off.

Specifications

For details, download the datasheet below.

Options

-LC: Current limiting

Front panel adjustable 10% to 105% of maximum output current.

-LW: Slow start

10 second HV output ramp up

-LG: Connector for GPIB, RS-232C, RS485, USB Interface.

(CO-HV adapter is required. Please refer to CO-HV series datasheet for details.)

-L(230V): Input Voltage AC230 V ±10% single phase

-L(3m): The length of HV output shielded cable is changed to 3 m.

-L(5m): The length of HV output shielded cable is changed to 5 m.

(only for ≤ 40 kV models)

-L(7m): The length of HV output shielded cable is changed to 7 m.

(only for ≤ 10 kV models)

How to order

When ordering, add Option No. to Model No. in alphabetical, order followed by the input voltage, and the cable length.
Example: AF-60P1-LCGW(230V)(3m)

Dimensions

For details, download the datasheet below.

Cable

Input

Standard
CABLE TYPE 1 (with 3 pin plug)
Rated Voltage Max. current
125 V 10 A
CABLE TYPE 1 Power Input End CABLE TYPE 1 Input Plug
with -L(230V) option
CABLE TYPE 3 (Flying lead)
Rated Voltage Max. current
250 V 10 A
CABLE TYPE 3 Power Input End CABLE TYPE 3 Input Plug

Output

CN-□-MHVP
CN-MHVP

Download

The account registration is necessary for downloading

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Please click here if you are not registered yet to our site.

Membership Registration (Free)

Please click here if you are already registered to our site.

Log in

High Voltage power supplies (Rack Mount/Benchtop)

Search for related to High Voltage power supplies (Rack Mount/Benchtop)