Discontinued
Low noise high voltage power supply
Precision rack mount
- Max Voltage: 1 to 150 kV
- Max Current: 0.1 to 120 mA
- Max Power: 10 to 300 W
- Local and remote operation
Wide line-up of high voltage power supply from 1 kV to 150 kV and 30 W to 300 W
The AF series has long been a bestseller at Matsusada Precision, recognized for its high performance and reliability as a standard high-voltage power supply.
Engineered with proprietary switching circuits, the series achieves exceptionally low ripple and spike noise, providing stable high-voltage output suitable for demanding applications. It is particularly effective for research and development uses, including electron microscopy and mass spectrometry, where high accuracy is essential.
With a proven track record of reliability, the AF series features multi-layered protection circuits for safe operation. Additionally, it comes standard with essential remote control and monitoring functions, making it easy to integrate into Automatic Test Equipment (ATE) systems.
Features and Benefits
- Wide lineup of high voltage power supply from 1 kV to 150 kV and 30 W to 300 W
- Local and remote operation
- Front panel adjustable overload trip level
- Remote and front panel monitoring of DC output voltage and current
- Automatic protection against overload, short circuit, and arc.
- GPIB interface option
- Digital interface option
Applications
- Electron Microscope
- Voltage reference
- Electronic component evaluation test
- Electron Beam
- X-ray tube
- Electron gun
- Ion Beam
- Insulation breakdown test
- Electron Beam Lithography (EBL)
- Scanning Electron Microscope (SEM)
- All kinds of High-Voltage Testing
Models
| Model | Max Output | |||
|---|---|---|---|---|
| Voltage | Current | Power | Ripple | |
| AF-1P30 | 1 kV | 30 mA | 30 W | 100 ppm |
| AF-1P60 | 60 mA | 60 W | ||
| AF-1P120 | 120 mA | 120 W | ||
| AF-3P10 | 3 kV | 10 mA | 30 W | 100 ppm |
| AF-3P20 | 20 mA | 60 W | ||
| AF-3P40 | 40 mA | 120 W | ||
| AF-3P60 | 60 mA | 180 W | ||
| AF-3P80 | 80 mA | 240 W | ||
| AF-5P6 | 5 kV | 6 mA | 30 W | 100 ppm |
| AF-5P12 | 12 mA | 60 W | ||
| AF-5P25 | 25 mA | 125 W | ||
| AF-5P35 | 35 mA | 175 W | ||
| AF-5P50 | 50 mA | 250 W | ||
| AF-10P3 | 10 kV | 3 mA | 30 W | 100 ppm |
| AF-10P6 | 6 mA | 60 W | ||
| AF-10P12 | 12 mA | 120 W | ||
| AF-10P18 | 18 mA | 180 W | ||
| AF-10P25 | 25 mA | 250 W | ||
| AF-10P30 | 30 mA | 300 W | ||
| AF-20P1.5 | 20 kV | 1.5 mA | 30 W | 100 ppm |
| AF-20P3 | 3 mA | 60 W | ||
| AF-20P6 | 6 mA | 120 W | ||
| AF-20P9 | 9 mA | 180 W | ||
| AF-20P12 | 12 mA | 240 W | ||
| AF-20P15 | 15 mA | 300 W | ||
| AF-30P1 | 30 kV | 1 mA | 30 W | 100 ppm |
| AF-30P2 | 2 mA | 60 W | ||
| AF-30P4 | 4 mA | 120 W | ||
| AF-30P6 | 6 mA | 180 W | ||
| AF-30P8 | 8 mA | 240 W | ||
| AF-30P10 | 10 mA | 300 W | ||
| AF-40P0.75 | 40 kV | 0.75 mA | 30 W | 100 ppm |
| AF-40P1.5 | 1.5 mA | 60 W | ||
| AF-40P3 | 3 mA | 120 W | ||
| AF-40P4.5 | 4.5 mA | 180 W | ||
| AF-40P6 | 6 mA | 240 W | ||
| AF-40P7.5 | 7.5 mA | 300 W | ||
| AF-50P0.6 | 50 kV | 0.6 mA | 30 W | 100 ppm |
| AF-50P1.2 | 1.2 mA | 60 W | ||
| AF-50P2.5 | 2.5 mA | 125 W | ||
| AF-50P3.5 | 3.5 mA | 175 W | ||
| AF-50P5 | 5 mA | 250 W | ||
| AF-60P0.5 | 60 kV | 0.5 mA | 30 W | 100 ppm |
| AF-60P1 | 1 mA | 60 W | ||
| AF-60P2 | 2 mA | 120 W | ||
| AF-60P3 | 3 mA | 180 W | ||
| AF-60P4 | 4 mA | 240 W | ||
| AF-80P0.75 | 80 kV | 0.75 mA | 60 W | 100 ppm |
| AF-80P1.5 | 1.5 mA | 120 W | ||
| AF-100P0.1 | 100 kV | 0.1 mA | 10 W | 100 ppm |
| AF-100P0.3 | 0.3 mA | 30 W | ||
| AF-100P0.6 | 0.6 mA | 60 W | ||
| AF-100P1 | 1 mA | 100 W | ||
| AF-100P1.2 | 1.2 mA | 120 W | ||
| AF-120P0.5 | 120 kV | 0.5 mA | 60 W | 100 ppm |
| AF-120P1 | 1 mA | 120 W | ||
| AF-150P0.5 | 150 kV | 0.5 mA | 75 W | 100 ppm |
| AF-150P0.8 | 0.8 mA | 120 W | ||
| Model | Max Output | |||
|---|---|---|---|---|
| Voltage | Current | Power | Ripple | |
| AF-1N30 | 1 kV | 30 mA | 30 W | 100 ppm |
| AF-1N60 | 60 mA | 60 W | ||
| AF-1N120 | 120 mA | 120 W | ||
| AF-3N10 | 3 kV | 10 mA | 30 W | 100 ppm |
| AF-3N20 | 20 mA | 60 W | ||
| AF-3N40 | 40 mA | 120 W | ||
| AF-3N60 | 60 mA | 180 W | ||
| AF-3N80 | 80 mA | 240 W | ||
| AF-5N6 | 5 kV | 6 mA | 30 W | 100 ppm |
| AF-5N12 | 12 mA | 60 W | ||
| AF-5N25 | 25 mA | 125 W | ||
| AF-5N35 | 35 mA | 175 W | ||
| AF-5N50 | 50 mA | 250 W | ||
| AF-10N3 | 10 kV | 3 mA | 30 W | 100 ppm |
| AF-10N6 | 6 mA | 60 W | ||
| AF-10N12 | 12 mA | 120 W | ||
| AF-10N18 | 18 mA | 180 W | ||
| AF-10N25 | 25 mA | 250 W | ||
| AF-10N30 | 30 mA | 300 W | ||
| AF-20N1.5 | 20 kV | 1.5 mA | 30 W | 100 ppm |
| AF-20N3 | 3 mA | 60 W | ||
| AF-20N6 | 6 mA | 120 W | ||
| AF-20N9 | 9 mA | 180 W | ||
| AF-20N12 | 12 mA | 240 W | ||
| AF-20N15 | 15 mA | 300 W | ||
| AF-30N1 | 30 kV | 1 mA | 30 W | 100 ppm |
| AF-30N2 | 2 mA | 60 W | ||
| AF-30N4 | 4 mA | 120 W | ||
| AF-30N6 | 6 mA | 180 W | ||
| AF-30N8 | 8 mA | 240 W | ||
| AF-30N10 | 10 mA | 300 W | ||
| AF-40N0.75 | 40 kV | 0.75 mA | 30 W | 100 ppm |
| AF-40N1.5 | 1.5 mA | 60 W | ||
| AF-40N3 | 3 mA | 120 W | ||
| AF-40N4.5 | 4.5 mA | 180 W | ||
| AF-40N6 | 6 mA | 240 W | ||
| AF-40N7.5 | 7.5 mA | 300 W | ||
| AF-50N0.6 | 50 kV | 0.6 mA | 30 W | 100 ppm |
| AF-50N1.2 | 1.2 mA | 60 W | ||
| AF-50N2.5 | 2.5 mA | 125 W | ||
| AF-50N3.5 | 3.5 mA | 175 W | ||
| AF-50N5 | 5 mA | 250 W | ||
| AF-60N0.5 | 60 kV | 0.5 mA | 30 W | 100 ppm |
| AF-60N1 | 1 mA | 60 W | ||
| AF-60N2 | 2 mA | 120 W | ||
| AF-60N3 | 3 mA | 180 W | ||
| AF-60N4 | 4 mA | 240 W | ||
| AF-80N0.75 | 80 kV | 0.75 mA | 60 W | 100 ppm |
| AF-80N1.5 | 1.5 mA | 120 W | ||
| AF-100N0.1 | 100 kV | 0.1 mA | 10 W | 100 ppm |
| AF-100N0.3 | 0.3 mA | 30 W | ||
| AF-100N0.6 | 0.6 mA | 60 W | ||
| AF-100N1 | 1 mA | 100 W | ||
| AF-100N1.2 | 1.2 mA | 120 W | ||
| AF-120N0.5 | 120 kV | 0.5 mA | 60 W | 100 ppm |
| AF-120N1 | 1 mA | 120 W | ||
| AF-150N0.5 | 150 kV | 0.5 mA | 75 W | 100 ppm |
| AF-150N0.8 | 0.8 mA | 120 W | ||
| Model | Max Output | |||
|---|---|---|---|---|
| Voltage | Current | Power mA | Ripple | |
| AF-1R30 | 1 kV | 30 mA | 30 W | 100 ppm |
| AF-1R60 | 60 mA | 60 W | ||
| AF-1R120 | 120 mA | 120 W | ||
| AF-3R10 | 3 kV | 10 mA | 30 W | 100 ppm |
| AF-3R20 | 20 mA | 60 W | ||
| AF-3R40 | 40 mA | 120 W | ||
| AF-3R60 | 60 mA | 180 W | ||
| AF-3R80 | 80 mA | 240 W | ||
| AF-5R6 | 5 kV | 6 mA | 30 W | 100 ppm |
| AF-5R12 | 12 mA | 60 W | ||
| AF-5R25 | 25 mA | 125 W | ||
| AF-5R35 | 35 mA | 175 W | ||
| AF-5R50 | 50 mA | 250 W | ||
| AF-10R3 | 10 kV | 3 mA | 30 W | 100 ppm |
| AF-10R6 | 6 mA | 60 W | ||
| AF-10R12 | 12 mA | 120 W | ||
| AF-10R18 | 18 mA | 180 W | ||
| AF-10R25 | 25 mA | 250 W | ||
| AF-10R30 | 30 mA | 300 W | ||
| AF-20R1.5 | 20 kV | 1.5 mA | 30 W | 100 ppm |
| AF-20R3 | 3 mA | 60 W | ||
| AF-20R6 | 6 mA | 120 W | ||
| AF-20R9 | 9 mA | 180 W | ||
| AF-20R12 | 12 mA | 240 W | ||
| AF-20R15 | 15 mA | 300 W | ||
| AF-30R1 | 30 kV | 1 mA | 30 W | 100 ppm |
| AF-30R2 | 2 mA | 60 W | ||
| AF-30R4 | 4 mA | 120 W | ||
| AF-30R6 | 6 mA | 180 W | ||
| AF-30R8 | 8 mA | 240 W | ||
| AF-30R10 | 10 mA | 300 W | ||
| AF-40R0.75 | 40 kV | 0.75 mA | 30 W | 100 ppm |
| AF-40R1.5 | 1.5 mA | 60 W | ||
| AF-40R3 | 3 mA | 120 W | ||
| AF-50R0.6 | 50 kV | 0.6 mA | 30 W | 100 ppm |
| AF-50R1.2 | 1.2 mA | 60 W | ||
| AF-50R2.5 | 2.5 mA | 125 W | ||
| AF-60R0.5 | 60 kV | 0.5 mA | 30 W | 100 ppm |
| AF-60R1 | 1 mA | 60 W | ||
| AF-60R2 | 2 mA | 120 W | ||
| AF-80R0.75 | 80 kV | 0.75 mA | 60 W | 100 ppm |
| AF-100R0.1 | 100 kV | 0.1 mA | 10 W | 100 ppm |
| AF-100R0.3 | 0.3 mA | 30 W | ||
Polarity Reversal: For models up to 60 kV, polarity can be reversed by swapping the internal cable. For models rated 80 kV and above, polarity is reversed by swapping the internal high-voltage module.
Example:AF-1R30: 0 to ±1 kV/0 to 30 mA
Functions
Normal Operation: Output (1) to (5), conversely to stop operation.
- POWER ON/OFF switch: This has priority over all operations.
- High Voltage ON/OFF switch
Output is enabled when this is ON.
The remote switch can be turned ON/OFF only when the high-voltage switch is ON. This switch is also used for resetting interlock and cut off mode. - COARSE potentiometer (10-turn, lockable)
- FINE potentiometer (10-turn, lockable)
- Overload trip level setting dial: 1-turn LED is lit up when the protection circuit is operating.
- Ground (GND) Terminal (M6)
- AC Inlet
- Fuse
- Output connector (Matsusada precision's property)
- Output voltage monitor
- Output current monitor
- Connector for USB, RS-232C, RS-485, and GPIB interface, and changing-over switch (option)
REMOTE CONTROL CONNECTOR M4
REMOTE SWITCH ON/OFF *
| Output | External relay | Open collector |
|---|---|---|
| ON | Short | VCE ≤ 0.4 V |
| OFF | Open | VCE ≥ 2 V |
Sink Current ≥ 10 mA
OUTPUT CONTROL
| Output voltage | LR | Vcon |
|---|---|---|
| 0 to MAX | R2 0 to 5 kΩ |
0 to 10 V Input imp ≥ 10 kΩ |
Output is possible in external relay short or a status of VCE less than 0.4 V.
The output will be cut off when open or 2 V or remote. To work again, turn the OUTPUT switch ON after resetting by turning the OUTPUT switch OFF in a status of short or 0.4 V or less.
* -LG option: When the switch (12) is on the IEEE-488 side, the remote switch and output control are not enabled from a remote terminal but from only the IEEE-488 operation.
DOOR SWITCH
Sink Current ≥ 10 mA
Output is possible in external relay short or a status of VCE less than 0.4 V.
Output will be cut off when open or 2 V or more. To output again, turn the OUTPUT switch ON after resetting by turning the OUTPUT switch OFF in a status of short or 0.4 V or less.
* -LG option: When switch (12) is on IEEE-488 side, remote switch and output control is not enable from remote terminal, but from only IEEE-488 operation.
OUTPUT MONITOR BNC receptacle *
- Vout: 0 to ±10 V(0 to +10 V)
- [standard] Monitor polarity equals output polarity
- [-LG option] Positive polarity regardless of High Voltage polarity
- Iout: 0 to +10 V
Output imp is 1 kΩ.
* -LG option: Generates output no matter switch (12) is on or off.
Specifications
Options
- -LC
-
Current limiting
Front panel adjustable 10% to 105% of maximum output current.
- -LW
-
Slow start
10-second High Voltage output ramp-up
- -LG
-
Connector for USB, LAN, RS-232C, RS-485, GPIB Interface.
(CO-HV adapter is required. Please refer to the CO/USB series datasheet for details.)
- -L(230V)
-
Input Voltage AC230 V ±10% single phase
- -L(3m)
-
Change the length of the High-voltage output shielded cable to 3 meters.
- -L(5m)
-
Change the length of the High-voltage output shielded cable to 5 meters. (only for ≤ 40 kV models)
- -L(7m)
-
Change the length of the High-voltage output shielded cable to 7 meters. (only for ≤ 10 kV models)
How to order
When ordering, add Option No. to Model No. in alphabetical, order followed by the input voltage, and the cable length.
Example: AF-60P1-LCGW(230V)(3m)
Accessories
Digital remote control adapter
LAN / USB / RS-232C / RS-485 / GPIB Control
To remotely control this high-voltage power supply via LAN or USB, purchase both a digital converter (CO-HV) and an optical isolation adapter. The digital converter (CO-HV) converts the analog control signal of the high-voltage power supply into a digital optical signal. The optical isolation adapter converts interface signals such as LAN and USB to optical signals.
For details, check the CO / USB series for a digital converter (CO-HV) and optical isolation adapter.
- Optical isolation
- 16-bit (1/65535) high-resolution A / D .
- Computer and PLC controlled.
- Protecting from discharge and surge.
- Ideal for automation and labor-saving systems.
Input cable
| [Standard] | CABLE TYPE1 | 125 V / 10 A | 2.5 meters Fixed length |
||
|---|---|---|---|---|---|
| [Standard] with -L(230V) option |
CABLE TYPE3 | 250 V / 10 A | 2.5 meters Fixed length |
||
| [Sold separately] | CABLE TYPE4 | 250 V / 10 A | 2.5 meters Fixed length |
||
| [Sold separately] | CABLE TYPE13 | 250 V / 15 A | 2.5 meters |
Output Cable
|
Standard 1 kV to 15 kV models, 20 kV to 30 kV models, 40 kV models, 50 kV to 60 kV models, 80 kV to 120 kV models, 150 kV models |
CN-□-MHVP |
Depending on the output voltage, the length will be varied. |
2.5 meters (Specified length available) |
|---|
Dimensions
Download
If you are unable to download a file
Please try the following solution.
- Please press Ctrl+F5 to clear the cache of your web browser and try again.
- Please restart your web browser and log in again to try again.
- Please change your web browser to another browser and try again.
- Restart the computer and try again.
- Please try again on a different computer.

-
AF series Datasheet
Date: 2022-04-18 rev. 02
PDF (1,975 KB)

-
Safety and Usage of High voltage Power supply
Date: 2025-09-08 rev 04
PDF (602 KB)
Login Required

-
AF series Datasheet
Date: 2022-04-18 rev. 02
PDF (1,975 KB)

-
Safety and Usage of High voltage Power supply
Date: 2025-09-08 rev 04
PDF (602 KB)
On this website, we provide only the latest versions of information and instruction manuals for our products. Therefore, the newest versions of manuals on the website may differ from those that came with products you purchased in the past.