High Voltage Power Supplies (Benchtop / Rack Mount)
This selection guide introduces Matsusada Precision's lineup of AC-input programmable high-voltage power supplies. The range includes benchtop models, rack-mount systems, application-specific products, and high-voltage pulse power supplies, enabling you to identify the optimal solution for your requirements. For embedded applications requiring compact modules without metering or front panels, please visit the High Voltage Modules page.
INDEX
Benchtop Type
| Series |
ES |
EQ |
EPR |
EJ |
EP |
CZE |
|---|---|---|---|---|---|---|
| Output Power | 3 to 15 W | 30 W | 30 to 150 W | 200 W | 4 to 5 W | 7.5 W |
| 1 kV | 1 kV | 1 kV | 1 kV | ±1 kV | ||
| 1.5 kV | 1.5 kV | 1.5 kV | ±1.5 kV | |||
| 2 kV | 2 kV | ±2 kV | ±2 kV | |||
| 3 kV | 3 kV | 3 kV | 3 kV | |||
| 5 kV | 5 kV | 5 kV | ±5 kV | |||
| 10 kV | 10 kV | 10 kV | ||||
| 15 kV | 15 kV | |||||
| 20 kV | 20 kV | |||||
| 30 kV | 30 kV | 30 kV | ±30 kV | |||
| Feature | Ultra Compact | Ultra Compact | Ultra Compact | |||
| High Stability | High Stability | |||||
| Ultra Low Ripple | Low Ripple | |||||
| Wide output range | ||||||
| Output polarity reversible | Output polarity reversible | |||||
| Ripple | 5 mVp-p | 0.05 %p-p | 0.1 %p-p | 0.1 %p-p | 15 mVp-p | 0.1 %p-p |
| Applications | Automatic Test Equipment, ATE |
Automatic Test Equipment, ATE |
||||
| Electrostatic testing | Electrostatic testing | |||||
| PMT/MCP | PMT | |||||
| Electron Beam | Electron Beam | |||||
| Ion Beam | Ion Beam | |||||
| For Biasing | For Biasing |
Rack Mount Type
| Series |
HARS |
AU |
AE |
AK |
AKP |
AUH |
ASX |
AESS |
HEB |
HIB |
XPg |
XKg |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output Power | 0.5 to 3 kW | 0.03 to 2.2 kW | 15 to 120 W | 3 to 6.4 kW | 12 to 13 kW | 1.2 to 2 kW | 15.5 W | 15 to 30 W | Multi-channel | Multi-channel | 0.6 to 4 kW | 15 W to 4 kW |
| 1 kV | 1 kV | 1 kV | 1 kV | 1 kV | 1 kV | |||||||
| 1.5 kV | 1.5 kV | 1.5 kV | 1.5 kV | 1.5 kV | ||||||||
| 2 kV | 2 kV | 2 kV | 2 kV | |||||||||
| 3 kV | 3 kV | 3 kV | 3 kV | 3 kV | 3 kV | |||||||
| 3.1 kV | ± 3.1 kV | |||||||||||
| 3.6 kV | 3.6 kV | |||||||||||
| 4 kV | 4 kV | |||||||||||
| 5 kV | 5 kV | 5 kV | 5 kV | 5 kV | 5 kV | |||||||
| 6 kV | 6 kV | 6 kV | 6 kV | 6 kV | ||||||||
| 7.5 kV | ||||||||||||
| 10 kV | 10 kV | 10 kV | 10 kV | 10 kV | 10 kV | 10 kV | -10 kV | |||||
| 12 kV | 12 kV | 12 kV | ||||||||||
| 15 kV | 15 kV | 15 kV | 15 kV | 15 kV | -15 kV | |||||||
| 20 kV | 20 kV | 20 kV | 20 kV | 20 kV | ||||||||
| 30 kV | 30 kV | 30 kV | 30 kV | 30 kV | 30 kV | 30 kV | -30 kV | -30 kV | 30 kV | |||
| 40 kV | 40 kV | 40 kV | 40 kV | 40 kV | 40 kV | -40 kV | 40 kV | |||||
| 50 kV | 50 kV | 50 kV | 50 kV | 50 kV | -50 kV | -50 kV | 50 kV | |||||
| 60 kV | 60 kV | 60 kV | 60 kV | 60 kV | 60 kV | -60 kV | 60 kV | |||||
| 70 kV | 70 kV | 70 kV | ||||||||||
| 80 kV | 80 kV | 80 kV | 80 kV | 80 kV | 80 kV | |||||||
| 100 kV | 100 kV | 100 kV | 100 kV | 100 kV | 100 kV | -100 kV | 100 kV | |||||
| 120 kV | 120 kV | 120 kV | 120 kV | 120 kV | 120 kV | 120 kV | ||||||
| 140 kV | 140 kV | |||||||||||
| 150 kV | 150 kV | 150 kV | ||||||||||
| 160 kV | 160 kV | -160 kV | 160 kV | |||||||||
| 180 kV | 180 kV | |||||||||||
| 200 kV | 200 kV | |||||||||||
| Feature | Ultra High Stability | High Stability | High Stability | Ultra High Stability | Ultra High Stability | High Stability | High Stability | |||||
| Low Ripple | Low Ripple | Ultra Low Ripple | Ultra Low Ripple | Ultra Low Ripple | Ultra Low Ripple | Low Ripple | Low Ripple | |||||
| Standard LAN and USB communication interfaces | Local and remote operation | Local and remote operation | Local and remote operation | |||||||||
| Low Profile and High Power | Low Profile and Lightweight | Extensive Lineup | Low Cost | |||||||||
| Pulse/Ramp Sequence | ||||||||||||
| Ripple | 0.05 %p-p | less than 0.1 %p-p | 0.0001 % Vrms | 0.1 %p-p + 1 Vrms | 0.3 %p-p + 1 Vrms | 0.3 %p-p 0.1 %p-p, at 3-phase 200 V option selected |
1 mVp-p | 10 mVp-p | 0.1 Vp-p | 0.4 Vp-p | Less than 0.03 %rms | Less than 0.03 %rms |
| General Purpose Use | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Dedicated for E-beam and SEM | Dedicated for I-beam and FIB | Dedicated, X-ray Power Supply | Dedicated, X-ray Power Supply |
| Applications | All kinds of high-voltage testing | All kinds of high-voltage testing | All kinds of high-voltage testing | All kinds of high-voltage testing | All kinds of high-voltage testing | All kinds of high-voltage testing | All kinds of high-voltage testing | All kinds of high-voltage testing | Scanning electron microscope (SEM) | Focused Ion Beam (FIB) | X-ray tube (anode-grounded type) |
X-ray tube (cathode-grounded type) |
| Automatic Test Equipment, ATE |
Automatic Test Equipment, ATE |
Automatic Test Equipment, ATE |
Electron Gun, Electron Beam | Ion Gun, Ion Beam | ||||||||
| Series |
HARS |
AU |
AE |
AK |
AKP |
AUH |
ASX |
AESS |
HEB |
HIB |
XPg |
XKg |
Application-Specific Products
Capillary Electrophoresis
Low-Noise, Reversible Power Supplies for Electrophoresis
- Voltage range: 0 to +30/0 to -30kV
- Current: 0 to 250μA
- Ripple: 0.1 %p-p
Electron Beam, Electron Gun
Multi-output high-voltage power supplies designed for electron beam and electron gun applications.
- Accelerator voltage: -10 to -60 kV
- Ripple: 0.1 Vp-p
Ion Beam, Ion Gun
Multi-output high-voltage power supplies optimized for ion beam and ion gun applications.
- Accelerator voltage: +10 to +60 kV
- Ripple: 0.4 Vp-p
X-Ray tube (for anode-grounded type)
High stability, low ripple, negative-output X-ray power source
- Voltage range: -30 to -160kV
- Current: 4 to 67 mA
- Ripple: Less than 0.03 %rms
X-Ray tube (for cathode-grounded type)
X-ray power supply for cathode-grounded X-ray tubes.
- Voltage range: 30 to 160kV
- Current: 0.21 to 67mA
- Ripple: Less than 0.03 %rms
High Voltage Pulse Power Supplies
These high-voltage pulse power supplies are engineered for applications including ion beam deflection, synchrotron radiation measurement, PMT, and MCP driving.