FOUR-QUADRANT BIPOLAR AMPLIFIER
Ultra High Speed Response
- Output Voltage:
±75 V or ±150 V - Output Power:
75 W to 300 W - Frequency Bandwidth:
DC to 1 MHz - Wonder Broadband
Stable operation regardless of load impedance, featuring wide bandwidth and high-speed response from DC to 1 MHz
The DOA series is a four-quadrant bipolar amplifier featuring wide bandwidth and ultra-high-speed response from DC to 1 MHz.
It is ideal for transient response testing, effectively utilizing its high-speed characteristics. Capable of operating as both a DC power supply and an electronic load, it can drive various loads, including inductive loads such as transformers, capacitive loads such as capacitors, and piezoelectric elements.
This versatile series delivers maximum current even at DC output.
Note: This product is not designed for charge and discharge of battery.
For battery charging and discharging applications, please refer to the Battery Cycle Tester product page.
Features and Benefits
- High-speed response of DC to 1 MHz or 500 kHz.
- Four-quadrant operation capable of sourcing and sinking current.
- Equipped with a DC bias function (DC offset voltage setting).
- Capable of outputting maximum current at DC.
- Reliable design featuring overvoltage, overcurrent, and output short-circuit protections.
Applications
- Evaluation tests for inductive loads such as coils and transformers.
- Voltage fluctuation tests for electric elements of cars.
- Evaluation tests for capacitive loads such as capacitors or display panels.
- Ripple test for capacitors.
- Evaluation tests of various motors.
- Evaluation tests of relative equipment to solar panels.
- Drive of piezo elements, etc.
Models
Each model will be brought to the market sequentially. Please confirm with our sales staff the detailed period of sale for the models you want prior to ordering.
Functions
Protections
Overvoltage Protection (OVP)
Equipped with overvoltage protection, this unit limits the output voltage to approximately 110% of the rating, protecting the load during fault conditions.
Overcurrent Protection (OCP)
Equipped with overcurrent protection, this unit limits the output current to approximately 110% of the rating, protecting both the power supply and the load during overload.
High-speed Overcurrent Protection
This unit features two types of overcurrent protection: a high-speed circuit to limit pulse currents and a standard circuit for static currents. The standard protection limits continuous currents with a response speed of approximately 1 ms. The high-speed protection circuit limits pulse currents (e.g., square waves or capacitive loads) to approximately twice the rated current.
Output Range
This unit is a bipolar power supply that is possible to operate in four-quadrant behavior. It is able to source or sink current in the ranges as shown in the following figure.
Specifications
- Input voltage
- 100 to 240 Vac, 50/60 Hz, Single-phase
- Output control
-
[External control signal] Vcon-in, Input voltage -3 to +3 V
[Front panel] DC bias: 10-turn potentiometer with -100% to +100% setting
Options
- -LN
-
Automatic Output Recovery
This option retains the output state when recovering from an input power interruption, such as toggling the AC power switch or a power failure.
This eliminates the need to manually reset the protection status or turn the OUTPUT switch off and on again.
Caution: If the power is turned on while the OUTPUT switch is set to ON, the unit will output voltage immediately.
- -LVs
-
The output range is shifted
- Shifting following 3 ranges is possible for ±75 V output models.
- (L) -125 V to +25 V
- (M) -75 V to +75 V
- (H) -25 V to +125 V
- Shifting following 3 ranges is possible for ±150 V output models.
- (L) -250 V to +50 V
- (M) -150 V to +150 V
- (H) -50 V to +250 V
This knob is attached to the front panel.
How to Order
When placing an order, please add the option code(s) after the model name.
If adding two or more options, omit the “-L” from the second and subsequent option codes, and list them in alphabetical order.
[Example] DOA150-2-LNVs
Accessories
- Function Generator
- AC input cable
-
Standard CABLE TYPE1 125 V/10 A 2.5 meters
Fixed lengthSold separately CABLE TYPE3 250 V/10 A 2.5 meters
Fixed lengthSold separately CABLE TYPE4 250 V/10 A 2.5 meters
Fixed length
Dimensions
Tech Notes
Capacitive Load
If the capacitive load exceeds 100 pF (including stray capacitance of the output wire), output resonance may occur. In such cases, insert a high-voltage resistor of 100 Ω (for 0.1 μF) to 1000 Ω (for 1000 pF) in series with the output. Please note that the frequency bandwidth is limited when driving a capacitive load, as shown in the formula on the right.
Additionally, in applications such as corona discharge, currents exceeding the rating may flow, potentially damaging the amplifier. In these cases, as with capacitive loads, please install an output limiting resistor.
* Avoid continuous input of high-frequency signals that exceed the amplifier's output capabilities, as this increases internal loss and may cause failure.
Download
If you are unable to download a file
Please try the following solution.
- Please press Ctrl+F5 to clear the cache of your web browser and try again.
- Please restart your web browser and log in again to try again.
- Please change your web browser to another browser and try again.
- Restart the computer and try again.
- Please try again on a different computer.

-
DOA series Datasheet
Date: 2025-07-03 rev 12
PDF(1,618 KB)

-
Bipolar Power Supplies Selection Guide Via External Signal input
Date: 2025-06-30 rev 08
PDF (4,774 KB)

-
Bipolar Power Supplies/Amplifiers Selection Guide
Date: 2023-10-17 rev.03
PDF (6,310 KB)

-
DOA series Instruction Manual
Date: 2024-02-09 rev 0.0
PDF (1,162 KB)
Login Required

-
DOA series Datasheet
Date: 2025-07-03 rev 12
PDF(1,618 KB)

-
Bipolar Power Supplies Selection Guide Via External Signal input
Date: 2025-06-30 rev 08
PDF (4,774 KB)

-
Bipolar Power Supplies/Amplifiers Selection Guide
Date: 2023-10-17 rev.03
PDF (6,310 KB)

-
DOA series Instruction Manual
Date: 2024-02-09 rev 0.0
PDF (1,162 KB)