Yes. Our battery cycle testers can be used for the performance tests specified in IEC 62620 (and its equivalent standard, JIS C8715-1).
This standard defines the performance and labeling requirements for secondary lithium cells and batteries used in industrial applications.
- JIS C8715-1 (≈IEC 62620) test items that can be performed with the CD series and CDPU series
-
- Charging procedure for test purposes
- Discharge performance
- Low-temperature discharge performance
- High-rate discharge performance
- Charge (capacity) retention and recovery
- Cycle life endurance
- Storage endurance
- These tests can be inspected using the CD series.
Please note that our testers do not support the measurement of AC and DC internal resistance, which is also specified in the standard.