Are battery performance tests as specified in IEC 61960 supported?

Category
Battery Cycle Testers FAQs

Yes, the CD, CDPU and PBR/PBRM series support the electrical test profiles defined in IEC 61960.
This standard specifies the performance tests and requirements for secondary lithium cells and battery packs.

IEC 61960 (≈JIS C8711) test items supported by the CD, CDPU and PBR/PBRM series:
  • Discharge performance (Rated capacity at 20 °C)
  • Discharge performance at -20 °C
  • High-rate discharge performance at 20 °C
  • Charge retention and recovery after short-term (28-day) storage
  • Charge recovery after long-term (90-day) storage
  • Cycle life endurance (Cycle life test)

The CD, CDPU and PBR/PBRM series are designed to perform these charge and discharge sequences.
Please note that other tests specified in the standard, such as internal resistance measurement and electrostatic discharge (ESD) testing, are not supported by these models.