XR series
X-ray Power Supply
- Max Power: 50 W to 100 W
- For cathode X-ray tube
- Compact and High Power
(For some models)
X-ray Power Supply for grounded Cathode X-ray tubes
This compact module incorporates adjustable beam, bias and filament supplies for low power X-ray applications. High voltage and filament current ramp up linearly for fast starts. Constant emission current is adjustable from 0 to full output for precise emission control.
Features
- For grounded Cathode X-ray Tubes
- Compact High Power 50 W to 100 W
- 0.05% Emission current regulation
- Remote and local emission control
- Adjustable filament current
- Safety interlock
- Overvoltage and short circuit protection.
- CE certified for 50 W and 75 W of 50 kV model.
Models
Model * | Output Voltage [kVdc] | Output Current [mA] | Input Current | Filament Supply |
---|---|---|---|---|
XR-305-50-## | 0 to +30 | 1.67 | 4 A max | 0.3 Adc to 3.5 Adc, adjustable. Compliance Voltage 4.5 V (9 W max) |
XR-505-50-## | 0 to +50 | 1 | 4 A max | |
XR-505-75-## | 1.5 | 6 A max | ||
XR-505-100-## | 2 | 8 A max | ||
XR-605-60-## | 0 to +60 | 1 | 4.8 A max | |
XR-655-50-## | 0 to +65 | 0.77 | 4 A max |
* Each product of XR is adjusted most suitably to each model of X-ray tube. According to the suitable X-ray tube, it is classified by a suffixed number to the model number. When ordering, please advise us the part number and manufacturer of the X-ray tube to be used. According suitable model to the X-ray tube is selected, and an appropriate part number is to be informed.
Specifications
Options
-LB: Bias Supply
0 V to -300 V adjustable, output current 0.25 mA
-LGH: LGH-3I connector
How to Order
To order, please add "-L" to the model number.Example: XR-505-50-01-LBGH
Dimensions
Download
-
XR series Datasheet
Date: 2020-07-21 rev. 10
PDF (594 KB)
-
Safety and Usage of High voltage Power supply
Date: 2020-10-09 rev. 02
PDF (1,366 KB)
-
X-ray Power Supplies Selection Guide
Last updated: March 27, 2020 rev. 02
PDF (1,169 KB)
-
XR series Manual
PDF(238KB)
The account registration is necessary for downloading
-
XR series Datasheet
Date: 2020-07-21 rev. 10
PDF (594 KB)
-
Safety and Usage of High voltage Power supply
Date: 2020-10-09 rev. 02
PDF (1,366 KB)
-
X-ray Power Supplies Selection Guide
Last updated: March 27, 2020 rev. 02
PDF (1,169 KB)
-
XR series Manual
PDF(238KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.