Searching...

  • XKg series
  • XKg series

X-RAY HIGH VOLTAGE POWER SUPPLY

  • For Cathode ground X-ray tubes
  • Voltage range: 30 to 160kV
  • Current: 0.21 to 67mA
  • Power: 15 to 4000W

X-RAY HIGH VOLTAGE POWER SUPPLIES CATHODE GROUND TYPE

XKg series is high stability and low ripple positive X-ray power supply with integrated filament supply and generates stable x-ray output. Interlock and useful functions are installed for safer and more convenient operation.
With the combination with digital controller CO/USB series, control via LAN, USB, GPIB, RS-232C, and RS-485 is available.

FEATURES AND BENEFITS

  • High voltage power supplies designed for X-ray tubes used in X-ray Non-Destructive Testing (NDT) and X-Ray Fluorescence (XRF) analysis
  • Up to 4 kW output power models are also available.
  • for Cathode ground type X-ray tubes
  • Integrated filament supply
  • Low ripple and high stability
  • Digital interface
  • Constant voltage/current operation with full protection for safety operation
  • Custom X-ray control option available
  • OEM customization availabble

APPLICATIONS

COMPATIBLE X-RAY TUBE

XRF X-ray tube, Liquid-cooled X-ray tubes, Shielded X-ray tube, Molded X-ray tube, Glass X-ray tube, Beryllium window X-ray tube, Ceramics X-ray tube.
About X-ray tubes and high-voltage power supplies

Models

Model Output
Voltage Current Power
XKg-30P0.5 30 kV 0.5 mA 15 W
XKg-30P1 1 mA 30 W
XKg-30P2 2 mA 60 W
XKg-30P3.3 3.3 mA 100 W
XKg-40P0.5 40 kV 0.5 mA 20 W
XKg-40P0.75 0.75 mA 30 W
XKg-40P1.5 1.5 mA 60 W
XKg-40P2.5 2.5 mA 100 W
XKg-40P3.75 3.75 mA 150 W
XKg-50P0.6 50 kV 0.6 mA 30 W
XKg-50P1.2 1.2 mA 60 W
XKg-50P2 2 mA 100 W
XKg-50P3 3 mA 150 W
XKg-50P4 4 mA 200 W
XKg-60P0.5 60 kV 0.5 mA 30 W
XKg-60P1 1 mA 60 W
XKg-60P1.6 1.6 mA 100 W
XKg-60P2.5 2.5 mA 150 W
XKg-60P50 50 mA 3000 W
XKg-60P67 67 mA 4000 W
XKg-80P0.37 80 kV 0.37 mA 30 W
XKg-80P0.75 0.75 mA 60 W
XKg-80P1.25 1.25 mA 100 W
XKg-80P1.87 1.87 mA 150 W
XKg-80P40 40 mA 3200 W
XKg-80P50 50 mA 4000 W
XKg-100P0.3 100 kV 0.3 mA 30 W
XKg-100P0.6 0.6 mA 60 W
XKg-100P1 1 mA 100 W
XKg-100P1.5 1.5 mA 150 W
XKg-100P3 3 mA 300 W
XKg-120P0.25 120 kV 0.25 mA 30 W
XKg-120P0.5 0.5 mA 60 W
XKg-120P0.83 0.83 mA 100 W
XKg-120P1.25 1.25 mA 150 W
XKg-120P2.5 2.5 mA 300 W
XKg-140P0.21 140 kV 0.21 mA 30 W
XKg-140P0.42 0.42 mA 60 W
XKg-140P0.71 0.71 mA 100 W
XKg-140P1.07 1.07 mA 150 W
XKg-140P2.14 2.14 mA 300 W
XKg-160P0.62 160 kV 0.62 mA 100 W
XKg-160P0.93 0.93 mA 150 W
XKg-160P1.87 1.87 mA 300 W

Specifications

For details, download the datasheet below.

Options

-LB

Bias output
-300 V variable 2.5 mA

-LT1

Interlock remote reset, Output state auto-recovery prevention
(former: power failure protection) remote reset

-L(200V)

200 Vac to 240 Vac single phase (only for up to 300 W models)

-L(200V1P)

200 Vac to 220 Vac single phase (only for 3000 W model)

-L(5m)

Changing the output cable length to be 5 meters
(The high voltage output cable for 30kV to 60kV is 5 meters instead of 2.5 meters.)

How to Order

When ordering, add Option No. in the following order by alphabet and input voltage to Model No.
Option code is ordered alphabetically and by input voltage value.
Example: XKg-160P1.87-LBT1(200V) with CNXK-160-3P(5)

Accessories

Digital remote control adapter

LAN / USB / RS-232C / RS-485 / GPIB Control

To remotely control this high-voltage power supply via LAN or USB, purchase both an digital converter (CO-HV) and optical isolation adapter. The digital converter (CO-HV) converts the analog control signal of the high-voltage power supply into a digital optical signal. The optical isolation adapter converts interface signals such as LAN and USB to optical signals.

For details, check the CO / USB series for a digital converter (CO-HV) and optical isolation adapter.

  • Optical isolation
  • 16-bit (1/65535) high-resolution A / D .
  • Computer and PLC controlled.
  • Protecting from discharge and surge.
  • Ideal for automation and labor-saving systems.
Refer to CO/USB series
CO/USB series | Digital controllers | Matsusada Precision

AC Input Cable

Model Cable Type Power Input End Input Plug Rated Voltage Rated Maximum
Standard
15 W to 300 W model
CABLE TYPE 1
CABLE TYPE 1 CABLE TYPE 1 125 Vac 10 A
Standard
15 W to 300 W model
-L(200V) option
CABLE TYPE 3
CABLE TYPE 3 CABLE TYPE 3 250 Vac 10 A
Sold separately
15 W to 300 W model
-L(200V) option
CABLE TYPE 4
CABLE TYPE 4 CABLE TYPE 4 250 Vac 25 A
Standard
3000 W model
4000 W model
CABLE TYPE 6
CABLE TYPE 6 CABLE TYPE 6 250 Vac 10 A

Output Cable

Standard
30 kV model
CN-30-MHVP CN-30-MHVP 2.5 meters
(Specified length
available)
Standard
40 kV model
CN-45-MHVP CN-45-MHVP 2.5 meters
(Specified length
available)
Standard
50 kV and 60 kV model
CN-60-MHVP CN-45-MHVP 2.5 meters
(Specified length
available)
Standard
80 kV to 120 kV model
CN-120AR-MHVP CN-120AR-MHVP 2.5 meters
(Specified length
available)
* Standard cable length is 2.5 meters. For 5 meter length, suffix(5) to the model number.
Example CN-120AR-MHVP(5)
Sold separately
140 kV and 160 kV model
CNXK-160-3P(5),
CNXK-160-3P(10)
CN-XK-160-3P cable length
(5): 5 meters
(10): 10 meters

For more details, refer to CN series.

Dimensions

For details, download the datasheet below.

Download

The account registration is necessary for downloading

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Please click here if you are not registered yet to our site.

Membership Registration (Free)

Please click here if you are already registered to our site.

Log in

High Voltage power supplies (Benchtop/Rackmount)