X-RAY HIGH VOLTAGE POWER SUPPLY
- For Cathode ground X-ray tubes
- Voltage range: 30 to 160kV
- Current: 0.21 to 67mA
- Power: 15 to 4000W
X-RAY HIGH VOLTAGE POWER SUPPLIES CATHODE GROUND TYPE
XKg series is high stability and low ripple positive X-ray power supply with integrated filament supply and generates stable x-ray output.
Interlock and useful functions are installed for safer and more convenient operation.
With the combination with digital controller CO/USB series, control via LAN, USB, GPIB, RS-232C, and RS-485 is available.
FEATURES AND BENEFITS
- High voltage power supplies designed for X-ray tubes used in X-ray Non-Destructive Testing (NDT) and X-Ray Fluorescence (XRF) analysis
- Up to 4 kW output power models are also available.
- for Cathode ground type X-ray tubes
- Integrated filament supply
- Low ripple and high stability
- Digital interface
- Constant voltage/current operation with full protection for safety operation
- Custom X-ray control option available
- OEM customization availabble
APPLICATIONS
- X-Ray Fluorescence (XRF)
- X-ray Non-Destructive Testing (NDT)
- X-ray Food Inspection
- X-ray Spectroscopy, X-ray Spectrometer
- X-ray Irradiation
- X-Ray source/X-Ray tube
- More List of X-ray applications
COMPATIBLE X-RAY TUBE
XRF X-ray tube, Liquid-cooled X-ray tubes, Shielded X-ray tube, Molded X-ray tube, Glass X-ray tube, Beryllium window X-ray tube, Ceramics X-ray tube.
About X-ray tubes and high-voltage power supplies
Models
Model | Output | ||
---|---|---|---|
Voltage | Current | Power | |
XKg-30P0.5 | 30 kV | 0.5 mA | 15 W |
XKg-30P1 | 1 mA | 30 W | |
XKg-30P2 | 2 mA | 60 W | |
XKg-30P3.3 | 3.3 mA | 100 W | |
XKg-40P0.5 | 40 kV | 0.5 mA | 20 W |
XKg-40P0.75 | 0.75 mA | 30 W | |
XKg-40P1.5 | 1.5 mA | 60 W | |
XKg-40P2.5 | 2.5 mA | 100 W | |
XKg-40P3.75 | 3.75 mA | 150 W | |
XKg-50P0.6 | 50 kV | 0.6 mA | 30 W |
XKg-50P1.2 | 1.2 mA | 60 W | |
XKg-50P2 | 2 mA | 100 W | |
XKg-50P3 | 3 mA | 150 W | |
XKg-50P4 | 4 mA | 200 W | |
XKg-60P0.5 | 60 kV | 0.5 mA | 30 W |
XKg-60P1 | 1 mA | 60 W | |
XKg-60P1.6 | 1.6 mA | 100 W | |
XKg-60P2.5 | 2.5 mA | 150 W | |
XKg-60P50 | 50 mA | 3000 W | |
XKg-60P67 | 67 mA | 4000 W | |
XKg-80P0.37 | 80 kV | 0.37 mA | 30 W |
XKg-80P0.75 | 0.75 mA | 60 W | |
XKg-80P1.25 | 1.25 mA | 100 W | |
XKg-80P1.87 | 1.87 mA | 150 W | |
XKg-80P40 | 40 mA | 3200 W | |
XKg-80P50 | 50 mA | 4000 W | |
XKg-100P0.3 | 100 kV | 0.3 mA | 30 W |
XKg-100P0.6 | 0.6 mA | 60 W | |
XKg-100P1 | 1 mA | 100 W | |
XKg-100P1.5 | 1.5 mA | 150 W | |
XKg-100P3 | 3 mA | 300 W | |
XKg-120P0.25 | 120 kV | 0.25 mA | 30 W |
XKg-120P0.5 | 0.5 mA | 60 W | |
XKg-120P0.83 | 0.83 mA | 100 W | |
XKg-120P1.25 | 1.25 mA | 150 W | |
XKg-120P2.5 | 2.5 mA | 300 W | |
XKg-140P0.21 | 140 kV | 0.21 mA | 30 W |
XKg-140P0.42 | 0.42 mA | 60 W | |
XKg-140P0.71 | 0.71 mA | 100 W | |
XKg-140P1.07 | 1.07 mA | 150 W | |
XKg-140P2.14 | 2.14 mA | 300 W | |
XKg-160P0.62 | 160 kV | 0.62 mA | 100 W |
XKg-160P0.93 | 0.93 mA | 150 W | |
XKg-160P1.87 | 1.87 mA | 300 W |
Specifications
Options
- -LB
-
Bias output
-300 V variable 2.5 mA
- -LT1
-
Interlock remote reset, Output state auto-recovery prevention
(former: power failure protection) remote reset
- -L(200V)
-
200 Vac to 240 Vac single phase (only for up to 300 W models)
- -L(200V1P)
-
200 Vac to 220 Vac single phase (only for 3000 W model)
- -L(5m)
-
Changing the output cable length to be 5 meters
(The high voltage output cable for 30kV to 60kV is 5 meters instead of 2.5 meters.)
How to Order
When ordering, add Option No. in the following order by alphabet and input voltage to Model No.
Option code is ordered alphabetically and by input voltage value.
Example: XKg-160P1.87-LBT1(200V) with CNXK-160-3P(5)
Accessories
Digital remote control adapter
LAN / USB / RS-232C / RS-485 / GPIB Control
To remotely control this high-voltage power supply via LAN or USB, purchase both an digital converter (CO-HV) and optical isolation adapter. The digital converter (CO-HV) converts the analog control signal of the high-voltage power supply into a digital optical signal. The optical isolation adapter converts interface signals such as LAN and USB to optical signals.
For details, check the CO / USB series for a digital converter (CO-HV) and optical isolation adapter.
- Optical isolation
- 16-bit (1/65535) high-resolution A / D .
- Computer and PLC controlled.
- Protecting from discharge and surge.
- Ideal for automation and labor-saving systems.

AC Input Cable
Model | Cable Type | Power Input End | Input Plug | Rated Voltage | Rated Maximum |
---|---|---|---|---|---|
Standard 15 W to 300 W model |
CABLE TYPE 1 |
125 Vac | 10 A | ||
Standard 15 W to 300 W model -L(200V) option |
CABLE TYPE 3 |
250 Vac | 10 A | ||
Sold separately 15 W to 300 W model -L(200V) option |
CABLE TYPE 4 |
250 Vac | 25 A | ||
Standard 3000 W model 4000 W model |
CABLE TYPE 6 |
250 Vac | 10 A |
Output Cable
Standard 30 kV model |
CN-30-MHVP | ![]() |
2.5 meters (Specified length available) |
---|---|---|---|
Standard 40 kV model |
CN-45-MHVP | ![]() |
2.5 meters (Specified length available) |
Standard 50 kV and 60 kV model |
CN-60-MHVP | ![]() |
2.5 meters (Specified length available) |
Standard 80 kV to 120 kV model |
CN-120AR-MHVP | ![]() |
2.5 meters (Specified length available) |
- * Standard cable length is 2.5 meters. For 5 meter length, suffix(5) to the model number.
- Example CN-120AR-MHVP(5)
Sold separately 140 kV and 160 kV model |
CNXK-160-3P(5), CNXK-160-3P(10) |
![]() |
cable length (5): 5 meters (10): 10 meters |
---|
Dimensions
Download
-
XKg series Datasheet
Date: 2023-03-01 rev.12
PDF (1,855 KB)
-
X-ray tube General Guide
Date: 2023-03-08 rev.04
PDF (3,605 KB)
-
Safety and Usage of High voltage Power supply
Date: 2020-10-09 rev. 02
PDF (1,366 KB)
-
XKg series Instruction Manual
Date: 2020-12-28 rev. 0.4
PDF (770 KB)
The account registration is necessary for downloading
-
XKg series Datasheet
Date: 2023-03-01 rev.12
PDF (1,855 KB)
-
X-ray tube General Guide
Date: 2023-03-08 rev.04
PDF (3,605 KB)
-
Safety and Usage of High voltage Power supply
Date: 2020-10-09 rev. 02
PDF (1,366 KB)
-
XKg series Instruction Manual
Date: 2020-12-28 rev. 0.4
PDF (770 KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.