Rack Mount High Voltage Power Supplies AK series

  • AK series
  • AK series

AK series

Compact Rack-mount High Voltage Power Supply

  • Max Voltage: 1kV to 120kV
  • Max Current: 150mA to 6000A
  • Max Power: 3000W to 6400W
  • Various Remote Control Functions

Suitable for the inspection and evalutions of inverter and power device

AK series is high-performance high voltage power supplies with high power output of 120 kV/6.4 kW in 19" rack. Users can select the best suitable model for each application among the wide lineup of more than 100 models to save the cost.
In addition to its low noise and stable HV outputs, AK series features various remote control options and complete protections to make it an easy-to-operate and highly reliable power supply for variety of applications.

AK series is a reliable HV power supply for voltage withstand testing for a various electrical components such as IGBT or breaker which are used in next generation power supply systems including DC power delivery or smart grid.

Features and Benefits

  • Wide range of output from 1 kV to 120 kV and 3.0 kW to 6.4 kW
  • Local and remote operation with various remote functions
  • Remote and front panel monitoring of DC output voltage and current
  • Automatic protection against overload, short circuit and arc
  • PC programmable via USB, Ethernet, RS-232C, RS-485 and GPIB (option)

Applications

Models

Positive polarity output

Model Maximum Output Weight [kg approx.]
Voltage [kV] Current Power [kW]
AK-1P3000 1 3A 3.0 25
AK-1P4000 4A 4.0 25
AK-1.5P2000 1.5 2A 3.0 25
AK-1.5P2660 2.66A 4.0 25
AK-1.5P4250 4.25A 6.4 40
AK-2P1500 2 1.5A 3.0 25
AK-2P2000 2A 4.0 25
AK-2P3200 3.2A 6.4 40
AK-3P1000 3 1A 3.0 25
AK-3P1060 1.06A 3.2 25
AK-3P1330 1.33A 4.0 25
AK-3P2100 2.1A 6.4 40
AK-3.6P1300 3.6 1.3A 4.6 40
AK-5P600 5 600 mA 3.0 25
AK-5P800 800 mA 4.0 25
AK-5P1280 1.28A 6.4 40
AK-6P500 6 500 mA 3.0 25
AK-6P670 670 mA 4.0 25
AK-6P1060 1.06A 6.4 40
AK-10P300 10 300 mA 3.0 25
AK-10P400 400 mA 4.0 25
AK-10P640 640 mA 6.4 40
AK-12P500 12 500 mA 6.0 40
AK-12P530 530 mA 6.4 40
AK-15P200 15 200 mA 3.0 25
AK-15P267 267 mA 4.0 25
AK-15P420 420 mA 6.4 40
AK-20P150 20 150 mA 3.0 25
AK-20P200 200 mA 4.0 25
AK-20P320 320 mA 6.4 40
AK-30P100 30 100 mA 3.0 25
AK-30P133 133 mA 4.0 25
AK-30P210 210 mA 6.4 40
AK-40P75 40 75 mA 3.0 25
AK-40P100 100 mA 4.0 25
AK-40P160 160 mA 6.4 40
AK-50P60 50 60 mA 3.0 25
AK-50P80 80 mA 4.0 25
AK-50P125 125 mA 6.4 40
AK-60P50 60 50 mA 3.0 25
AK-60P67 67 mA 4.0 25
AK-60P105 105 mA 6.4 40
AK-70P90 70 90 mA 6.4 50
AK-80P37.5 80 37.5 mA 3.0 50
AK-80P50 50 mA 4.0 50
AK-80P80 80 mA 6.4 50
AK-100P30 100 30 mA 3.0 50
AK-100P40 40 mA 4.0 50
AK-100P64 64 mA 6.4 50
AK-120P25 120 25 mA 3.0 50
AK-120P33 33 mA 4.0 50
AK-120P53 53 mA 6.4 50

Negative polarity output

Model Maximum Output Weight [kg approx.]
Voltage [kV] Current Power [kW]
AK-1N3000 1 3A 3.0 25
AK-1N4000 4A 4.0 25
AK-1.5N2000 1.5 2A 3.0 25
AK-1.5N2660 2.66A 4.0 25
AK-1.5N4250 4.25A 6.4 40
AK-2N1500 2 1.5A 3.0 25
AK-2N2000 2A 4.0 25
AK-2N3200 3.2A 6.4 40
AK-3N1000 3 1A 3.0 25
AK-3N1060 1.06A 3.2 25
AK-3N1330 1.33A 4.0 25
AK-3N2100 2.1A 6.4 40
AK-3.6N1300 3.6 1.3A 4.6 40
AK-5N600 5 600 mA 3.0 25
AK-5N800 800 mA 4.0 25
AK-5N1280 1.28A 6.4 40
AK-6N500 6 500 mA 3.0 25
AK-6N670 670 mA 4.0 25
AK-6N1060 1.06A 6.4 40
AK-10N300 10 300 mA 3.0 25
AK-10N400 400 mA 4.0 25
AK-10N640 640 mA 6.4 40
AK-12N500 12 500 mA 6.0 40
AK-12N530 530 mA 6.4 40
AK-15N200 15 200 mA 3.0 25
AK-15N267 267 mA 4.0 25
AK-15N420 420 mA 6.4 40
AK-20N150 20 150 mA 3.0 25
AK-20N200 200 mA 4.0 25
AK-20N320 320 mA 6.4 40
AK-30N100 30 100 mA 3.0 25
AK-30N133 133 mA 4.0 25
AK-30N210 210 mA 6.4 40
AK-40N75 40 75 mA 3.0 25
AK-40N100 100 mA 4.0 25
AK-40N160 160 mA 6.4 40
AK-50N60 50 60 mA 3.0 25
AK-50N80 80 mA 4.0 25
AK-50N125 125 mA 6.4 40
AK-60N50 60 50 mA 3.0 25
AK-60N67 67 mA 4.0 25
AK-60N105 105 mA 6.4 40
AK-70N90 70 90 mA 6.4 50
AK-80N37.5 80 37.5 mA 3.0 50
AK-80N50 50 mA 4.0 50
AK-80N80 80 mA 6.4 50
AK-100N30 100 30 mA 3.0 50
AK-100N40 40 mA 4.0 50
AK-100N64 64 mA 6.4 50
AK-120N25 120 25 mA 3.0 50
AK-120N33 33 mA 4.0 50
AK-120N53 53 mA 6.4 50
Following lineups are also avaliable beside above.
AU series: 1 kV to 120 kV/30 W to 2.2 kW
AKP series: 1 kV to 120 kV/12 kW, 13 kW
REH series: 750 V to 1.2 kV/1 kW to 15 kW

Options

-LF

Floating ground: isolate HV return from chassis ground (50 V max) *1
All equipments that connect to Remote Control Connector (TB1) must be on floating ground in case this feature is intended to use.
(To be used to measure the current flow to the load. This option cannot be used to float a high voltage power supply.)

-LW

Slow start: around 10 seconds from output switch or remote switch on to reach setting voltage *1

-LMs

Master slave control: 1 Master unit can control up to 2 slave units *1 *2
(Sum of maximum rating output must be under 18 kW)

-LOc

Cut off the output when overcurrent *2

-L(200V)

Input Voltage 200VAC ±10%, three-phase (Input current: approx. 105% of AC 208 V)

-L(230V)

Input Voltage 230VAC ±10%, three-phase (Input current: approx. 90% of AC 208 V)

-L(400V)

Input Voltage 400VAC ±10%, three-phase

  • (Input current: 3.0 kW 5.5 A typ.)
  • Input current: 3.2 kW 5.5 A typ.)
  • Input current: 4.0 kW 8 A typ.)
  • Input current: 4.6 kW 8.5 A typ.)
  • Input current: 6.0 kW 11 A typ.)
  • Input current: 6.4 kW 11 A typ.)

-L(3m)

The length of HV output shielded cable cable is changed to 3m.

-L(5m)

The length of HV output shielded cable is changed to 5m. (only for up to 40kV models)

-L(7m)

The length of HV output shielded cable is changed to 7m. (only for up to 15kV models)

  1. In case selecting -LMs option with -LF option or -LW option, all AK power supplies which connected as Master-Slave, need to equip -LF option and -LW option.
  2. In case power supply operate as cut off the output when overcurrent with Master-Slave connection, select -LOc option for only Master unit (the other options can be selected together), and do not select -LOc option for Slave unit. Combinations other than above, cut off the output when overcurrent will not work. And also, Slave unit does not equip -LOc option, therefore, if Slave unit is used individually,out will be either CC or CV as standard features.

Download

The account registration is necessary for downloading

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Please click here if you are not registered yet to our site.

Membership Registration (Free)

Please click here if you are already registered to our site.

Log in

High Voltage power supplies (Rack Mount/Benchtop)

Search for related to High Voltage power supplies (Rack Mount/Benchtop)