Benchtop
DC Electronic Loads

  • Operational Voltage range:
    1.5 Vdc to 150Vdc
  • Load current: 30A to 60A
  • Load power:
    150W, 200W, and 300W
  • World wide input

COMPACT AND HIGH POWER PROGRAMMABLE DC ELECTRONIC LOADS

EGD series is ideal for DC electronic loads for testing batteries, power supplies and power converters, aging test and so on.
They are able to build the charge and discharge system combined with our DC power supplies REK series or RK series with LAN, USB, RS-232C, RS-485, or GPIB interface.

FEATURES

  • Five units can be placed into a 19 inches Rack of 3U size. (150 W and 200 W models)
  • They are operable in two modes of Constant Current (CC) and Constant Resistance (CR).
  • Worldwide input is applicable to any commercial electric power source in the world.
  • Package control to 16 units is possible.

APPLICATIONS

  • Evaluation of switching power supply
  • Evaluation of DC/DC converter

Models

Model Rated voltage Rated current Maximum load power [W]
EGD150W-150V 150 V 30 A 150 W
EGD200W-150V 30 A 200 W
EGD300W-150V* Coming soon 60 A 300 W

* The load time of this model is different from other models, so please contact our sales office for details.

Functions

EGD series is light and compact!

Maximum load capacity 200W is realized

At the evaluation test of compact battery, which is not so much large, we also hope to place the load device compactly.
EGD series are just fitted the best electronic load for such a situation.
They can be utilized in Stand-Alone with operation on the front panel.

Weight: approx 3.6 kg

EGD series | DC Electronic Loads | Matsusada Precision

They can be utilized as DC electronic load of multi-channels

If the dedicated adapter (Sold separately) is used, a maximum of Five units of EGD series are placed in a rack of 19 inches and they can be utilized as a DC electronic load with multi-channel.

Following combination is able.

150 W and 200 W Models 300 W Model ch No.
5 units - 5 ch
4 units - 4 ch
3 units - 3 ch
2 units 1 units 3 ch
1 units 1 units 2 ch
- 2 units 2 ch

Digital interface

In addition to digital control via USB, LAN, RS-232C, RS-485, or GPIB collective control is enabled in the master/slave operation.

Adapters for connecting digital interface (sold separately)

To use the digital interface, you need to prepare a digital interface adapter separately. The following interface adapters are available according to the communication method of your controller port.

CO-E32m: Adapter for LAN
Total 16 units can be connected to one CO-E32m.
LAN cable is not provided.
CO-E32
CO-U32m: Adapter for USB
Total 16 units can be connected to one CO-U32m.
USB cable is not provided.
CO-U32m
CO-MET2-9: Adapter for RS-232C (9 pin)
Total 16 units can be connected to each CO-MET2-9.
CO-MET2-9
CO-MET2-25: Adapter for RS-232C (25 pin)
Total 16 units can be connected to each CO-MET2-25.
CO-MET2-25
CO-MET4-25: Adapter for RS-485 (25 pin)
Total 16 units can be connected to each CO-MET4-25.
CO-MET4-25
CO-G32m: Adapter for GPIB
Total 16 units can be connected to one CO-G32m.
GPIB cable is not provided.
CO-G32

For details, refer to CO/USB series datasheet.

-LGmb Digital interface board
(A) CO-M cable
A two-meter cable is provided in each unit without an interface option. If you need a longer cable, please consult with our sales staff.

Master/Slave control

The operations of up to 16 EG devices can be controlled from the master unit. (Not for increasing current by parallel connection)

In master/slave control, the connection will be made between the same models.
Electronic load EGD Series Master slave

Remote control

Switching Remote/Local

Switching Remote/Local
Model External Relay TTL
remote short LOW
local open HIGH

Load control and operation modes can be changed with relay or TTL signal.

Load Control

Load Control
Load Resistance/
Load Current
Control Voltage R
MIN to MAX 0 to 10 Vdc
Input impedance 500 kΩ
0 to approx. 10 kΩ

Voltage/Current Monitor

Voltage/Current Monitor
Input Voltage/current
0 to Max.
0 to 10 Vdc
Output Impedance 1 kΩ
0 to 10 Vdc
Output Impedance 1 kΩ

Status Output

Status Output

FLT...ON at the abnormal conditions
(ON at statuses of OCP, OVP, OPP, UVP, and OTP)

COMMON is floating at open collector output.
Withstand Voltage: 30 Vdc, Sink Current: ≤ 5 mA

Load ON/OFF

Remote switch
Load Relay Open collector
ON Short VCE ≤ 0.4 V
OFF Open VCE ≥ 2 V

Sink current: 1 mA

Specifications

For details, download the datasheet below.

Options

-L(Mc0.5), -L(Mc0.15): Changing cable length
Length of CO-M cable (refer to page 4) is 0.5 meter or 0.15 meter, respectively. (Please select either one.)

How to Order

When ordering, add Option No. to Model No.
Example: EGD150W-150V-L(Mc0.5)

Accessories

AC Input Cable

[Standard] CABLE TYPE1 CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 125 V / 10 A 2.5 meters

Fixed length

[Sold separately] CABLE TYPE3 CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 250 V / 10 A 2.5 meters

Fixed length

[Sold separately] CABLE TYPE4 CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 250 V / 10 A 2.5 meters

Fixed length

Dimensions

For details, download the datasheet below.

Download

If you are unable to download a file

Please try the following solution.

  1. Please press Ctrl+F5 to clear the cache of your web browser and try again.
  2. Please restart your web browser and log in again to try again.
  3. Please change your web browser to another browser and try again.
  4. Restart the computer and try again.
  5. Please try again on a different computer.

The account registration is necessary for downloading

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Please click here if you are not registered yet to our site.

Membership Registration (Free)

Please click here if you are already registered to our site.

Log in

Electronic Loads

Search for related to Electronic Loads