Searching...

High Voltage Amplifiers/High Voltage Pulse Power Supplies AMPS series

  • AMPS series | High Voltage Amplifier | Matsusada Precision
  • AMPS series | High Voltage Amplifier | Matsusada Precision

HIGH SPEED HIGH POWER HIGH VOLTAGE AMPLIFIER

  • Voltage range:
    ±0.6 kV to ±30 kV
  • Current:
    ±20 mA to ±2000 mA
  • Power: 400 W to 1200 W
  • Maximum slew rate 1200V/μs!
  • Full scale:
    DC to 100 kHz
  • Small bandwidth:
    DC to 200 kHz
  • CE marking
    (For some models)

ULTRA HIGH SLEW RATE 1200 V/μS

AMPS series is an ultra-high-speed, high voltage amplifier that offers an output up to ±30 kV or a very high slew rate of 1200 V/µs. The high current of peak current 4 A is also selectable.

FEATURES AND BENEFITS

  • Broad lineup ±0.6 kV to ±30 kV
  • Generous peak current output
  • 1. ULTRA HIGH SLEW RATE 1200 V/μS

    ±10 kV and ±20 kV output models achieved the existing double high-speed response of slew rate 1200 V/µs. Laser modulation and beam deflection at unprecedented high speed are possible.

    slew rate
  • 2. HIGH-SPEED RESPONSE OF FREQUENCY BANDWIDTH 100 KHZ

    Frequency bandwidth with actual load is as high as 100 kHz, and solve the problem of "When actual operation with load, the response become slow." Ideal for high speed printer or material evaluation testing.

    Voltage rise waveform (at ±0.6 kV, ±2 A output)
    Model: AMPS-0.6B2000 (at rated load)
    Amplifier AMPS Series Frequency response
  • 3. FOR MEASURING VOLTAGE AND CURRENT

    When the voltage at load is lower than the rated maximum output of AMPS series, constant voltage and high speed operation is possible by sinking the output current with current sink feature.
    As example of the development of ceramic and electrophotography process, by current sink, it is possible to absorb the voltage of a capacitive load quickly or to per form diselectrification smoothly.
    Peak current (1 ms) output is twice the rated DC current (see right figure, AMPS-10B40 and AMPS-20B20 are three times the rated current), the rise characteristics with capacitive loads can improve.

    OUTPUT RANGE
    (AMPS-0.6B2000)
    Amplifier AMPS series Output range

    * Output rms must be within 2 A

APPLICATIONS

  • Beam steering
  • Material characterization
  • Testing of solar panel, rechargeble battery and display panel
  • Particle accelerators
  • Electrophoresis
  • Various electrostatic deflection
  • Laser modulation

Models

CE mark: Conform to the CE (with low voltage directive) marking

Model Output Voltage
[kVdc]
Output Current Rated
output power
[W]
Slew Rate
[V/μs]
Frequency Response
(Typical value at sine wave operation
with resistive load)
Safety Standards
Full scale (-1 dB) * Small band width
(10% of full scale)(-3 dB)
AMPS-0.6B2000 -0.6 to +0.6 kV ±2000 mAmax or
±4000 mApk 1ms
1200 W 500 V/µs DC to 100 kHz DC to 200 kHz CE mark
AMPS-2B200 -2 to 2 kV ±200 mAmax or
±400 mApk 1 ms
400 W 1000 V/µs DC to 80 kHz DC to 160 kHz CE mark
AMPS-5B80 -5 to +5kV ±80 mAmax or
±160 mApk 1 ms
400 W 1000 V/µs DC to 50 kHz DC to 100 kHz CE mark
AMPS-10B40 -10 to +10 kV ±40 mAmax or
±120 mApk 1 ms
400 W 1200 V/µs DC to 20 kHz DC to 40 kHz CE mark
AMPS-20B20 -20 to +20 kV ±20 mAmax or
±60 mApk 1 ms
400 W 1200 V/µs DC to 10 kHz DC to 20 kHz CE mark
AMPS-30B20 -30 to +30 kV ±20 mAmax or
±40 mApk 1ms
600 W 800 V/µs DC to 5 kHz DC to 20 kHz -

* At frequency of full scale, output voltage may be clipped by power limitation.

Discontinued models

The following model is no longer available as we have stopped the production and sales. AMPS-0.6B2000 is available as the successor model.

Model Output Voltage
[kVdc]
Output Current Rated
output power
[W]
Slew Rate
[V/μs]
Frequency Response
(Typical value at sine wave operation with resistive load)
Full scale (-1 dB) * Small band width
(10% of full scale)(-3 dB)
AMPS-0.4B2000 -0.4 to +0.4 kV ±2000 mAmax or
±4000 mApk 1ms
800 W 400 V/µs DC to 100 kHz DC to 200 kHz

* At frequency of full scale, output voltage may be clipped by power limitation.

Options

-LC

Current Limit *
The output is not turn off but it is limited in the event of lowering output voltage at overcurrent level.

-LCc

Adjustable current limit level *
The output is not turn off but it is limited in the event of lowering output voltage at overcurrent level.
Using the potentiometer on the front panel, the limit current level can be adjusted in the range of 10% to 105% of the rating.

-LCx

Adjustable current trip level + Variable current limit level *
Both of -LOc (adjustable current trip level) and -LCc (adjustable current limit level) are switchable.

NOTE: As for models with -LCx option, the CE marking Low Voltage directive is not applicable.
-LN

Output state auto-recovery (former: no power failure protection)

-LOc

Adjustable current trip level *
Using the potentiometer on the front panel, the limit level to turn off the output current can be adjusted in the range of 10% to 105% of the rating.

-L(5m)

High voltage output cable 5 meters (more than 2 kV models)
When using a cable with 5 meters long, phenomena such as lower through rate or response speed or output waveform distortion may occur easily. Be careful to use it.

* These options can be chosen only one either. Selecting multiple options is unavailable at the same time.

How to Order

When ordering, add Option No. in the following order by alphabet, number, input voltage, and output cable length to Model No.
Example:AMPS-0.6B2000-LC

Accessories

Function Generator

Input cable
Standard
400 W and 600 W models
CABLE TYPE3 CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 250 V 2.5 meters
Standard
1200 W models
CABLE TYPE5 CABLE series | AC input cable | Matsusada Precision CABLE series | AC input cable | Matsusada Precision 250 V 2.5 meters
Output cable
Standard
Less than 0.6 kV models
Using terminal block 1.5 meters
Standard
2 kV to 10 kV models
CN-40-AHVP CN-40-AHVP
Flying lead (Non shielded cable)
1.5 meters
Standard
2 kV to 10 kV models
with -L(5m) option
CN-40-AHVP(5) 5 meters
Standard
AMPS-20B20
CN-40-AHVP TU CN-40-AHVP TU
Flying lead (Non shielded cable)
1.5 meters
Standard
AMPS-20B20
with -L(5m) option
CN-40-AHVP TU(5) 5 meters
Standard
AMPS-30B20
CN-50-AHVP CN-50-AHVP
Flying lead (No Shielded silicon)
3 meters

Dimensions

For details, download the datasheet below.

Download

If you are unable to download a file

Please try the following solution.

  1. Please press Ctrl+F5 to clear the cache of your web browser and try again.
  2. Please restart your web browser and log in again to try again.
  3. Please change your web browser to another browser and try again.
  4. Restart the computer and try again.
  5. Please try again on a different computer.

The account registration is necessary for downloading

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Please click here if you are not registered yet to our site.

Membership Registration (Free)

Please click here if you are already registered to our site.

Log in

Bipolar Power Supplies/High Voltage Amplifiers

Search for related to Bipolar Power Supplies/High Voltage Amplifiers